7 MAINTENANCE
7.
Clean the wire-feed roller with a soft brush.
8.
Clean the pressure roller attached to the tension arm with a soft brush.
9.
Close the tension arm on to the wire in its groove on the wire-feed rollers.
NOTE!
Verify that the wire is in the correct groove and not floating out of the groove
on the roller surface.
10. Visually verify that the wire appears as a straight line through the entire wire-feed
assembly.
NOTE!
The bobbin may be turned counter-clockwise to take up any slack. Do this
only AFTER step 12 because the tension on the wire is the only force
preventing the movement of the wire at the torch tip.
11. Visually verify that the wire protrudes per specification at the torch tip and has not
been pulled into the torch head.
12. Adjust the wire-feed pressure by adjusting the tension on the wire at the wire-feed
rollers by turning the tension knob.
13. Close the cover on the wire-bobbin side of the unit.
7.3

Rebel EMP 205ic AC/DC power side maintenance

NOTE!
There are no user-serviceable parts on the power-side. In dusty environments, the
power-side should be checked periodically for any dust/debris accumulation
because of the fan forced-air cooling used on this side.
Any maintenance on this side should be done by an authorized ESAB service
technician.
0463 652 101
- 52 -
© ESAB AB 2024

Advertisement