Outside Hoistway; Machine Room - Savaria Vuelift Mini Owner's Manual

Residential elevator
Hide thumbs Also See for Vuelift Mini:
Table of Contents

Advertisement

20

2. Outside Hoistway

*Minimum once a year is required
Verification by technician
Hall call
station and
lights
Hoistway
doors
Unlocking
device

3. Machine Room

*Minimum once a year is required
Verification by technician
Housekeeping
(Required
with Remote
Controller
Option)
Trash, used
parts, etc.
Controller and
starter
Vuelift Mini Owner's Manual
Examine the hall stations for
condition and replace all burnt out
lights. Observe operation of the
audible signal when the Emergency
Stop isactivated.
Examine the door panel and clearance
between the panel and entrance
frames. Examine proper interlock
functionality and operation. Adjust as
needed.
Examine the hoistway door unlocking
device for damage. Repair or adjust as
needed.
Clean the machine room floor to
prevent slipping and trip hazards, fire
hazards and contamination of the
equipment. Ensure the machine room
is not being used for storage and
inform the customer of any violation.
Ensure that all trash is discarded after
maintenance is complete.
Examine the controller and motor starter
for:
- Cleanliness
- Condition of contacts and remaining
contact material
- Fuses for correct size and fit in holders
and corrosion in fuse holder
- Relays for worn shunts and signs of
overheating
- Evidence of overheating
Frequency
Normal: Once a Year
Heavy: Every Year
Excessive:
Every 6 months
Normal: Once a Year
Heavy: Every Year
Excessive:
Every 6 months
Normal: Once a Year
Heavy: Every Year
Excessive:
Every 6 months
Frequency
Normal: Once a Year
Heavy: Every Year
Excessive:
Every 6 months
Normal: Once a Year
Heavy: Every Year
Excessive:
Every 6 months
Normal: Once a Year
Heavy: Every Year
Excessive:
Every 6 months
Part No. 001254, 31-m01-2024

Advertisement

Table of Contents
loading

Table of Contents