Troubleshooting
Turbidity sensor is the component that measures the amount of dirt in the water. The machine uses this data for the steps of Auto Pro-
gram (if applicable). If the proper data from the turbidity sensor cannot be received, Turbidity Sensor Error occurs. When the error
occurs, the program default will continue the program as heavy dirt level.
3Way / Multi Valve is the component that diverts the water flow between the upper and lower trays independently. It is driven by the
electronics and the position of the valve is measured by a feedback signal. Diverter Valve Position Error occurs if the proper position
signal could not be received from the valve. When the error occurs, the electronics drives the valve until proper position signal is
achieved.
Page 32 of 41
Turbidity fault E:04
Possible reasons:
•
Malfunction of Turbidity
Sensor
•
Cable harness errors
•
Faulty electronics
Diverter Valve Fault E:05
Possible reasons:
•
Malfunction of water diverter way valve
•
Cable harness errors
•
Faulty electronics