General Information
Press the time delay + tab again to go to the next item in the settings menu, Regeneration
level this will apply to WS (water softener) models only, see below.
Press the Select tab to change the current setting. r1 = no regeneration r2 = every 27.74 gal-
lons r3 = every 13.74 gallons (factory default) r4 = every 7.93 gallons r5 = every 2.38 gallons.
Press the time delay + tab again to go to the next item in the settings menu, Rinse Aid level ,
see below.
Press the Select tab to change the current setting. P0 = no rinse agent P1 = .05 ounces P2 =
.10 ounces P3 = .15 ounces (factory default) P4 = .20 ounces.