Paradyne 3760 User Manual page 57

Card modem
Hide thumbs Also See for 3760:
Table of Contents

Advertisement

AT Command Set and S-Registers
Table 4-2. S-Register Reference (5 of 6)
S-Register Description
S37= n
Maximum Allowable Data Rate
This S-Register selects the maximum allowable line speed.
For more information on this command, refer to Appendix D.
n = 0 DTE rate
n = 3 300 bps
n = 5 1200 bps
n = 6 2400 bps
n = 7 4800 bps
n = 8 7200 bps
n = 9 9600 bps
n = 10 12000 bps
n = 11 14400 bps
S90= n
Disconnect Inactivity Timer
This S-Register sets the length of time, in minutes, that the
modem will stay on-line/off-hook before disconnecting when
no data is transmitted or received. Any data transmitted or
received between the computer and the modem resets the
timer. A value is zero disables this feature.
n = 0–255 (minutes).
Factory setting is 0 (timer disabled).
4-24