Main Adjustment
@ Test Instruments reqired for adjustment
1. Digital osc cosilloscope (100MHz)
2. AM Standard signal generater
3. FM Standard signal generaler
4. Stereo modulator
5. Electric voltmeter
6. Digital tester
7. Tracking offset meter
8. Test Disc
JVC :CTS1000
9. Extension cable for check
EXTGS003-14P x 2
mM Standard measuring conditions
Power supply voltage
DC14.4V(10.5~16V)
Load impedance
4Q (2 Speakers connection)
Line out
20kQ
How
to connect the extension cable for adjusting
2-16
Standard volume position
Balance and Bass &Treble volume : Indication"0"
Loudness : Off
Setting of reference frequency of SSG
AM mode:
600kKHZ/62dB-INT/400Hz,30% modulation
Signal on
;
;
97.9MHZ/66dB/INT/400H2/22.5kHz deviation
pilot 7.5kHz dev.
FM mode:
Dummy load
Exclusive dummy load should be used for AM,and FM. For
FM dummy load,there is a loss of 6dB between SSG output
and antenna input.The loss of 6dB need not be considered
since direct reading of figures are applied in this working
standard.