Self-Test Results - Paradyne HotWire 7976 User Manual

M/sdsl standalone termination unit with g.703 interface
Hide thumbs Also See for HotWire 7976:
Table of Contents

Advertisement

Self-Test Results

7976-A2-GB20-10
The results of the last power-up or reset self-test appear in the middle column of
the System and Test Status screen.
Table 4-2. Self-Test Results Messages
Message
What Message Indicates
CPU Failed
The CPU failed internal testing.
Device
One or more of the Unit's integrated
Failed
circuit chips failed device-level
testing.
G.703
The Unit failed to loop data on the
Failed, Pt 1
G.703 on Port 1.
Memory
The Model 7976 Standalone
Failed
Termination Unit failed memory
verification.
FPGA
A failure in the FPGA was detected.
Failed, Pt1
DataPath
The unit failed to loop data between
Failed, Pt1
the G.703 Port and the DSL loop.
Failure
An internal failure occurred.
xxxxxxxx
(xxxxxxxx represents an eight-digit
hexadecimal failure code for use by
service personnel.)
Passed
No errors were detected.
August 1998
Monitoring the Unit
What To Do
1. Reset the unit and try again.
2. Call your service
representative for assistance.
1. Reset the unit and try again.
2. Call your service
2. Call your service
representative for assistance.
1. Reset the unit and try again.
2. Call your service
representative for assistance.
1. Reset the unit and try again.
2. Call your service
representative for assistance.
Record the failure code and
contact your service
representative.