Health And Status - Paradyne HotWire 7976 User Manual

M/sdsl standalone termination unit with g.703 interface
Hide thumbs Also See for HotWire 7976:
Table of Contents

Advertisement

Health and Status

7976-A2-GB20-10
The following messages can appear in the first column of the System and Test
Status screen. The highest priority Health and Status message also appears on
all ATI screens on the bottom right.
Table 4-1. Health and Status Messages (1 of 2)
Message
What Message Indicates
System Operational
There are no problems
detected.
LOS at Net, Pt 1
An LOS (Loss Of Signal)
condition has been
detected on the network
interface. No signal is
being received on Port 1,
possibly due to a local
network problem.
OOF at Net, Pt 1
An OOF (Out Of Frame)
condition has been
detected at the network
interface.
LOF at G.703, Pt 1
An LOF (Loss Of Frame)
condition has been
detected on the G.703
interface.
AIS at G.703, Pt 1
An Alarm Indication Signal
(AIS) is being received by
the G.703 interface.
EER at Net, Pt 1
An EER (Excessive Error
Rate) condition has been
detected on the network
interface at Port 1. The
condition is cleared when
the error rate falls below
the threshold value
currently configured.
EER at G.703, Pt 1
An EER (Excessive Error
Rate) condition has been
detected on the G.703
interface.
RAI (Remote Alarm
A Remote Alarm Indication
Indication) at G.703
signal is being received by
interface, Pt 1
the G.703 interface.
Net Margin
The signal-to-noise margin
Threshold, Pt 1
has exceeded the
configured threshold.
August 1998
Monitoring the Unit
What To Do
1. Verify that the network cable is
securely attached at both ends.
2. Verify proper NTU and LTU
configuration
3. Contact network provider.
Contact network provider.
1. Verify that the network cable is
securely attached at both ends.
2. Contact network provider.
1. Verify that the units line framing
and line coding are compatible.
2. Contact network provider.
Contact network provider.
1. Ignore condition if 511 test active.
2. Contact network provider.
Contact network provider.
1. Reconfigure the unit to a higher
Net Margin Threshold.
2. Contact network provider.
4-3

Advertisement

Table of Contents
loading

Table of Contents