T1 and e1 hdsl nest card termination units
Hide thumbs Also See for HOTWIRE 7924:
Table of Contents

Advertisement

HotWire Model 7924 Worksheets

HotWire 7924 Configuration Worksheet

A-4
2. The V.35-compatible standalone unit must have an HDSL firmware revision
number of 3 or higher.
To determine the firmware revision number of the V.35 standalone unit, look
at the label on the bottom of the standalone unit that has the "CE" and "CSA"
logos. The second row of numbers on this label should be"900P005705" or
higher. The last two digits of this number (05) indicate the hardware revision
number.
3. The V.35-compatible standalone unit must have a hardware revision number
of 5 or higher.
To determine the hardware revision number, look at the label on the bottom of
the standalone unit that has the "CE" and "CSA" logos. The second row of
numbers on this label should be "900P005705" or higher. The last two digits
of this number (05) indicate the hardware revision number.
Nest Card Configuration
Configuration Option
HDSL Card Type
Loops Enabled
T1 Line Encode
Line Build-Out
Framing
1
Customizing HotWire 7924 Nest Card Termination Units
Refer to Chapter 3,
switchpack location and configuration options.
2
UnFramed Operation
Refer to
Nest Card Configuration
Jumper
P12
August 1997
1
Settings
CP, CO
Loops A and B, Loop A
B8ZS, AMI
1) 0 to 133 feet – 0
2) 133 to 266 feet
3) 266 to 399 feet
4) 399 to 533 feet
5) 533 to 655 feet
D4, Extended Super Frame, Unframed
for unframed operation considerations.
Settings
(1, 2) Not used
(2, 3) Switchpack enabled
Default in Bold
2
, for information on
Default in [Bold]