Switchpack Definitions
7920-A2-GB20-10
Change configuration options by moving switchpack S1 DIP switches on the nest
card hardware.
Switchpack S1 Definitions
. . .
Position
#
Allows you to . . .
1
Control whether the board is an HTU-C (CO) or an HTU-R (CP).
OFF = CP
ON = CO
2
Control enabling and disabling of zeroes suppression in the line code.
OFF = AMI line encoding
ON = B8ZS line encoding
3
Change the DSL local loop configuration.
OFF = Loops A and B enabled
ON = Loop A enabled
4, 5, and 6
Change Line Build-out configuration.
000 = 0 to 133 feet
100 = 133 to 266 feet
010 = 266 to 399 feet
110 = 399 to 533 feet
001 = 533 to 655 feet
Positions 4, 5, and 6 form a three-digit binary number where ON
represents a value of 1 and OFF represents a value of 0. For example,
set 4 and 5 ON and 6 OFF for 399 to 533 feet.
7, 8
Control whether data is transmitted with or without framing.
00 = Unframed *
01 = D4
11 = ESF
Positions 7 and 8 form a two-digit binary number where ON represents
a value of 1 and OFF represents a value of 0. For example, set 7 OFF
and 8 ON for D4 framing.
NOTE:
* Some earlier units do not support unframed operation with V.35-compatible units. To
determine if your DSX-1-compatible unit supports unframed operation when
connected to a V.35-compatible standalone unit, refer to
Appendix A, HotWire Model 7924 Worksheets .
August 1997
Customizing HotWire 7924 Nest Card Termination Units
Operating unframed while T1 service is framed will result
in the loss of reporting certain performance statistics, for
example, CRC.
Configure your HotWire equipment to match the T1
network. If your T1 service is framed, configure your
HotWire 7900 nest cards as framed. If your T1 service is
unframed, configure your HotWire 7900 nest cards as
unframed.
Default in Bold
Unframed Operation
in
3-3