Glass Frosters Installation & Operation Manual
PREPARING THE CABINET - GLASS FROSTERS
Refrigerant
All models covered in this user manual are
manufactured using refrigerant R290 (Propane).
R290 is a hydrocarbon. This refrigerant is
471 (To cover potential risk originated from the
R290 is only allowed to be used in refrigerating
appliances which are designed for this
standard.
R290 is heavier than air. The concentration
The explosion limits are as follows:
- Lower Limit: 1.7% by vol. (37 g/m3)
- Upper Limit: 9.5% by vol. (177 g/m3)
- Ignition Temperature: 470 °C
Take caution when handling,
moving and using the
product to avoid damaging the refrigerant
tubing or increasing the risk of a leak.
All service work shall
be performed by factory
authorized service personnel and all
component parts shall be replaced with like
components to minimize the risk of possible
ignition due to incorrect parts or improper
service.
If service is necessary, repair
work must be performed by a
Perlick authorized servicer. Work done by
dangerous and will void the warranty.
Uncrating and Inspection
Remove all crating material. Carefully inspect
cabinet for hidden damage. If damage is
transport company. Perlick is not responsible for
damage in transit.
Printed in USA
Plumbing
No plumbing c onnections are r equired.
Condensate from the cooling coil automatically
evaporated through a condensate pan located in
the condensing unit section.
Electrical
The cabinet must be connected to a separately
and Local electrical codes.
Do not attempt to operate the
equipment on any other power
source than that listed on the Electrical
Adjustable Partitions & Shelving
Perlick Glass Frosters may be provided with
adjustable partitions and shelving which will
accommodate various bottle sizes.
c hi l le r ma ke s u re t o en s ur e p ro p e r
of the evaporator. Maintain at least 2" of
clearance on evaporator air intake and
exhaust for proper operation.
Installing Casters or Legs (optional)
Attach casters or legs to the cabinet bottom in
holes provided. Use the supplied 1/4" - 20 hex
head self-tapping machine screws. If unit is tipped
on its back, wait 24 hours after unit is uprighted
to plug the unit in.
Placing the Cabinet
To assure maximum performance, fresh air must
be allowed to circulate through the machinery
compartment. It is important to allow at least
two inches of clearance at the back or left end
of the cabinet. Do not place anything in front of
grilles. Do not place the unit in an unventilated
small room.
Removing the factory installed
b a c k c l e a r a n c e s p a c e r s
without providing proper left side grill
warranty.
4
void the
Need help?