Table 1. Hazardous Location Retention Accessories (Continued)
Port
Mini DisplayPort
SD Card Slot
Special Conditions for Hazardous Locations Use in Europe and
Internationally
The cDAQ-9136 has been evaluated as Ex nA IIC T4 Gc equipment under DEMKO
Certificate No. 12 ATEX 1202658X and is IECEx UL 14.0089X certified. Each device is
marked
II 3G and is suitable for use in Zone 2 hazardous locations, in ambient temperatures
of -20 °C ≤ Ta ≤ 55 °C.
Caution
the rated voltage.
Caution
Degree 2, as defined in IEC 60664-1.
Caution
a minimum ingress protection rating of at least IP54 as defined in IEC/EN 60079-15.
Caution
tool.

Power Requirements

Caution
used in a manner not described in the user documentation.
Note
Some C Series modules have additional power requirements. For more
information about C Series module power requirements, refer to the
C Series module(s) documentation.
Note
Sleep mode for C Series modules is not supported in the NI cDAQ-9136.
Voltage input range
Maximum power consumption
Recommended power supply
1
Includes maximum 1 W module load per slot across rated temperature and product variations.
Required Accessory
Mini DisplayPort Cable Retention Bracket
You must make sure that transient disturbances do not exceed 140% of
The system shall only be used in an area of not more than Pollution
The system shall be mounted in an ATEX/IECEx-certified enclosure with
The enclosure must have a door or cover accessible only by the use of a
The protection provided by the NI cDAQ-9136 can be impaired if it is
1
NI cDAQ-9136 Safety, Environmental, and Regulatory Information | © National Instruments | 3
SD Door Kit
9 to 30 V (measured at the NI cDAQ-9136
power connector)
40 W
100 W, 24 VDC
Part Number
156866-01
783660-01