Net to Net Technologies EIM2000 User Manual

Interface module 24/12-port e1 inverse multiplexer

Advertisement

Quick Links

210-0000054 rev02
EIM2000-12
12-Port E1 Inverse Multiplexer
EIM2000-24
24-Port E1 Inverse Multiplexer
http://www.nettonet.com
contact@nettonet.com
© Copyright 2003 Net to Net Technologies, Inc.
™ The Net to Net Logo is a trademark of Net to Net Technologies, Inc.
Worldwide Headquarters
Net to Net Technologies
112 Corporate Drive
Portsmouth, NH 03801
USA
1 (877) 638-2638
EIM2000 User Guide
Interface Module

User Guide

and
EMEA Headquarters
Net to Net Technologies
Victoria House 19 Park Way
Newbury Berkshire RG14 1EE
44 (0) 1635-570950
UK
Page 1 of 20

Advertisement

Table of Contents
loading

Summary of Contents for Net to Net Technologies EIM2000

  • Page 1: User Guide

    ™ The Net to Net Logo is a trademark of Net to Net Technologies, Inc. Worldwide Headquarters Net to Net Technologies 112 Corporate Drive Portsmouth, NH 03801 1 (877) 638-2638 EIM2000 User Guide Interface Module User Guide EMEA Headquarters Net to Net Technologies Victoria House 19 Park Way...
  • Page 2: Table Of Contents

    1.2.1 Switch 2 1.2.2 Switch 3 1.3 Install the EIM2000 in an IP DSLAM Chassis 1.3.1 Align the EIM2000 with the IP DSLAM Slot Module Guides 1.3.2 Slide the EIM2000 Firmly into the Chassis 1.3.3 Verify that the EIM2000 is Receiving Power 1.3.4 Secure the EIM2000 in the IP DSLAM Chassis...
  • Page 3: Installation

    E1 subscriber, if so desired, by placing Switch 3 in the DOWN position. Provider Mode You will NOT be able to set speed or timing configurations on an EIM2000 in subscriber mode. These settings will be determined via each port's communication with its respective partner E1 provider. 210-0000054 rev02...
  • Page 4: Install The Eim2000 In An Ip Dslam Chassis

    The IPD12000 and IPD12000E are fourteen slot chassis; slots 1-12 are reserved for interface modules (such as the EIM2000) and slots 13-14 are reserved for MUMs. Interface modules may be placed in any order in slots 1-12. The IPD4000 and IPD4000E are five slot chassis;...
  • Page 5: Slide The Eim2000 Firmly Into The Chassis

    1.3.2 Slide the EIM2000 Firmly into the Chassis DO NOT USE EXCESS FORCE. 210-0000054 rev02 EIM2000 User Guide Page 5 of 20...
  • Page 6: Verify That The Eim2000 Is Receiving Power

    1.3.3 Verify that the EIM2000 is Receiving Power The PWR (Power) LED on the EIM2000 faceplate will illuminate green. If your IP DSLAM is not yet powered up, refer to the IP DSLAM Installation Instructions for your model at http://www.nettonet.com/support/docs/#I 1.3.4 Secure the EIM2000 in the IP DSLAM Chassis...
  • Page 7: Connect The E1 Line(S)

    1.4.1 Local Connection 1.4.1.1 Select the Appropriate RJ21 Connector(s) E1 cables must be connected according to the IP DSLAM slot in which the EIM2000 was installed. In previous illustrations the EIM2000 was installed in Slot 3, therefore the E1 cable(s) should be plugged into the third RJ21 connector(s) from the right.
  • Page 8 RJ21 port located on the back of the chassis which will connect EIM2000 E1 ports 1-12. Although the EIM2000-24 can function in an IPD12000 or IPD4000, you will not be able to utilize ports 13-24; the IPD12000 and IPD4000 do not have the second row of B connectors necessary to support additional E1 ports.
  • Page 9 E1 connection can be made. This connection will support E1 ports 1-12 on both the EIM2000-12 and the EIM2000-24; you will not be able to utilize ports 13-24 on an EIM2000-24 installed in an IPD12000 or IPD4000. 210-0000054 rev02 EIM2000 User Guide...
  • Page 10 The RJ21 connector cannot be screwed into the connector frame on the IPD12000. An E1 connection on the IPD12000 can only be secured via the Velcro strap. 210-0000054 rev02 EIM2000 User Guide Page 10 of 20...
  • Page 11 Tuck the tab at the end of the Velcro strap above the connector frame towards the chassis so it is out of the way of other connections. 210-0000054 rev02 EIM2000 User Guide Page 11 of 20...
  • Page 12 1.4.1.4 RJ21 Port Pinouts 1.4.1.4.1 RJ21 Pins EIM2000 RJ21 Port RJ21 Connector 210-0000054 rev02 EIM2000 User Guide Page 12 of 20...
  • Page 13 1.4.1.4.2 A Connector Pinout (IPD12000E bottom row, IPD4000E left side, IPD12000 and IPD4000) EIM2000 E1 PORTS RJ21 PINS (pins 13 and 38 are not used) IPD12000E 210-0000054 rev02 A CONNECTORS Ring Ring EIM2000 User Guide Page 13 of 20...
  • Page 14 The EIM2000 is capable of supporting both single-line connections and multiple-line loop bonded connections, as well as any combination of the two. If the distance(s) between the EIM2000 and any of the remote E1 equipment is greater than 6,000 feet, the line(s) may require an E1 repeater.
  • Page 15 The E1 equipment to which an EIM2000 is connected must also be E1 loop bonding capable in order for the EIM2000 to establish a loop bonded connection. Refer to Net to Net's E1 Loop Bonding Product to Product Feature Compatibility document at http://www.nettonet.com/support/docs/230-0000035...
  • Page 16: Led Indications

    EIM2000 User Guide Additional Information If the Power LED is not illuminated, it is unlikely the EIM2000 is receiving power and none of the LEDs will be illuminated. The E1 link is operational and traffic is flowing. A connection exists but there is indication of a problem with the E1 line.
  • Page 17: Parameter Defaults

    ) and/or the CLI Management User Guide ( 0000052 ). Parameters specific to the EIM2000 are outlined below. 2.1 Parameter Defaults No configuration is necessary for the EIM2000 to operate at default settings. Parameter Local - provider mode Clock Source...
  • Page 18: Local (Default-Provider Mode

    2.2.2 Loop (default-subscriber mode) Timing is derives from an intermediate device on the E1 line. Local timing is the default for an EIM2000 in E1 provider mode. Default for an EIM2000 in subscriber mode is Loop and cannot be modified.
  • Page 19: Configuration And Management

    3.2 Data Storage Upon initial power up of the IP DSLAM, default parameters of the EIM2000 will remain in place unless changed via NMS, CLI or SNMP. Once changed, new configurations will automatically be recorded in both the Random Access Memory (RAM) of the EIM2000 and the Non-Volatile Random Access Memory (NVRAM) of the MUM.
  • Page 20 Net to Net Technologies 112 Corporate Drive Portsmouth, NH 03801 +1 877-638-2638 210-0000054 rev02 http://www.NetToNet.com/ Contact@NetToNet.com EIM2000 User Guide EMEA Headquarters Net to Net Technologies Victoria House 19 Park Way Newbury Berkshire RG14 1EE +44 (0) 1635 570950 Page 20 of 20...