Ambient; Refrigeration; Weight; Ice Production - Follett M25577 Operation And Service Manual

Table of Contents

Advertisement

Chassis drain plumbing
§ Plug must be removed from John Guest fitting.
§ Route 3/8" drain tubing through knockout in back of docking station and insert fully into John Guest fitting
connection at the rear of the machine chassis. Route other end of 3/8" drain tubing to drain.
§ Drain must slope 1/4" inch per foot (6 mm per 30.4 cm).

Ambient

Evaporator unit
Air temperature
Water temperature
Water pressure
Condenser unit
Air temperature

Refrigeration

§ 3/8" liquid line
§ 7/8" suction line
Rack system installations require a capacity of 15,700 BTU/hr for 1810 machines and 18,200 BTU/hr for
Note:
2110 machines at 0 F (–18 C) evaporator temperature. Evaporator pressure regulator (not supplied) is
required.

Weight

Evaporator unit:
1810: 157 lbs (71.2 kg)
2110: 165 lbs (74.8 kg)
Condensing unit: 305 lbs (138.3 kg)

Ice production

1810 ice machine capacity/24 hrs.
Ambient Air Temperature F/C
F
60
70
C
16
21
50
1859 1784 1685 1616 1500 lbs
10
843
809
60
1723 1684 1578 1563 1409 lbs
16
782
764
70
1620 1594 1514 1420 1319 lbs
21
734
723
80
1550 1487 1485 1351 1299 lbs
27
703
674
90
1471 1435 1370 1285 1207 lbs
32
667
651
6
100 F/38 C max.
90 F/32 C max.
70 psi max. (483 kPa)
120 F/49 C max.
80
90
100
27
32
38
764
733
680
kg
716
709
639
kg
687
644
598
kg
674
613
589
kg
621
583
547
kg
50 F/10 C min.
45 F/7 C min.
10 psi min. (69 kPa)
–20F/–29C min.
2110 ice machine capacity/24 hrs.
Ambient Air Temperature F/C
F
60
C
16
50
2039 2039
10
925
60
1943 1888
16
881
70
1833 1781
21
831
80
1754 1686
27
796
90
1650 1603
32
748
HC_1810R/N, HC_2110R/N, HM_1810R/N, HM_2110R/N
70
80
90
100
21
27
32
38
1934 1825 1703
925
877
828
772
1878 1710 1584
856
852
772
718
1789 1634 1489
808
811
741
675
1643 1535 1426
765
745
696
647
1577 1457 1395
727
715
661
633
lbs
kg
lbs
kg
lbs
kg
lbs
kg
lbs
kg

Advertisement

Table of Contents
loading