rollease acmeda AUTOMATE Manual

rollease acmeda AUTOMATE Manual

Paradigm remote control
Hide thumbs Also See for AUTOMATE:

Advertisement

AUTOMATE
Paradigm Remote Control
LEVEL CONTROL
AUTOMATE
| Paradigm remotes feature a contemporary design with touch sensitive
controls. Available in single and fifteen channel models, Paradigm remotes are
compatible with all ARC
FEATURES:
• Available in single channel & Fifteen Channel.
• Touch sensitive buttons.
• Levelling control (15 channel remote).
• LCD display (15 Channel remote).
• Hide unused channel function.
• Slim Magnetic wall mount.
TOUCH
SENSITIVE
motors.
433 MHz

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AUTOMATE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for rollease acmeda AUTOMATE

  • Page 1 AUTOMATE ™ Paradigm Remote Control TOUCH 433 MHz LEVEL CONTROL SENSITIVE AUTOMATE | Paradigm remotes feature a contemporary design with touch sensitive ™ controls. Available in single and fifteen channel models, Paradigm remotes are compatible with all ARC motors. ™...
  • Page 2: Table Of Contents

    6.2 Hide unused channels 6.3 Disable limit setting function of remote ADDING OR REMOVING CONTROLLERS & CREATING GROUP CHANNELS 7.1 Using Motor P1 Button 7.2 Using a pre-existing Controller TROUBLESHOOTING 2 | Automate ROLLEASE ACMEDA Programming Instructions | Paradigm Remotes ™...
  • Page 3: Technical Data / Pack Contents

    1 x magnetic holder inc. wall fixing screws 1 x Instruction manual 1 x 3V - CR2450 battery 1 x Small Phillips Head Screw - Battery Cover 1 x PH0 Screw Driver ROLLEASE ACMEDA Programming Instructions | Paradigm Remotes | 3 Automate ™...
  • Page 4: Safety Instructions

    • Always completely secure the battery compartment. If the battery compartment does not close securely, stop using the product, remove the batteries, and keep them away from children. 4 | Automate ROLLEASE ACMEDA Programming Instructions | Paradigm Remotes ™...
  • Page 5: Fcc & Ised Statement

    Consult the dealer or an experienced radio/TV technician for help. FCC ID: 2AGGZMTRFREM1C 21769-MTRFREM1C Do not dispose of in general waste. FCC ID: 2AGGZMTRFREM15 Please recycle batteries and damaged electrical products appropriately. 21769-MTRFREM15 ROLLEASE ACMEDA Programming Instructions | Paradigm Remotes | 5 Automate ™...
  • Page 6: Installation

    Battery simultaneously slide the battery cover down. Isolation Tab Note: On Startup, Remove Battery isolation tab. Install Battery Li-ion Cell Battery (CR2450) 6 | Automate ROLLEASE ACMEDA Programming Instructions | Paradigm Remotes ™...
  • Page 7: Functional Overview

    The levelling control bar can be used to visualize and accurately set your preferred shade position. When used to control a group of shades, they will all perfectly align to the same position. ROLLEASE ACMEDA Programming Instructions | Paradigm Remotes | 7 Automate ™...
  • Page 8: Selecting A Channel - (Multi Channel Remote)

    Group control using CH “0” Channel "0" is pre-set to control ALL shades paired within your multi-channel remote. To create a customized group channel ref to section 6 8 | Automate ROLLEASE ACMEDA Programming Instructions | Paradigm Remotes ™...
  • Page 9: Programming

    For 1 CH Screen flashes X 5 Screen flashes “1” = ARC Mode 1 Flash = ARC Mode Screen flashes “2” = EL Mode 2 Flashes = EL Mode ROLLEASE ACMEDA Programming Instructions | Paradigm Remotes | 9 Automate ™...
  • Page 10: Hide Unused Channels

    LED solid on when locked LCD displays “U” when unlocked LED blinking when unlocked It is still possible to add or delete channels and perform P2 functions, while the lock function is enabled. 10 | Automate ROLLEASE ACMEDA Programming Instructions | Paradigm Remotes ™...
  • Page 11: Adding Or Removing Controllers & Creating Group Channels

    Press P2 on existing Press P2 on existing Press P2 on new controller. controller. controller. Motor Response Motor Response Motor Response IMPORTANT Consult user manual for your controller or sensor. ROLLEASE ACMEDA Programming Instructions | Paradigm Remotes | 11 Automate ™...
  • Page 12: Troubleshooting

    SYSTEM BEST PRACTICE - Provide motor (multiple motors adjust motor limits an extra 15 channel remote in your respond) multi motor projects, that provides individual control for each motor for programming purposes. 12 | Automate ROLLEASE ACMEDA Programming Instructions | Paradigm Remotes ™...
  • Page 13 NOTES ROLLEASE ACMEDA Programming Instructions | Paradigm Remotes | 13 Automate ™...
  • Page 14 NOTES 14 | Automate ROLLEASE ACMEDA Programming Instructions | Paradigm Remotes ™...
  • Page 15 NOTES ROLLEASE ACMEDA Programming Instructions | Paradigm Remotes | 15 Automate ™...
  • Page 16 T +1 203 964 1573 | F +1 203 964 0513 ROLLEASE ACMEDA EUROPE Via Conca Del Naviglio 18, Milan (Lombardia) Italy T +39 02 8982 7317 | F +39 02 8982 7317 info@rolleaseacmeda.com rolleaseacmeda.com 16 | Automate Programming Instructions | Paradigm Remotes ™...

Table of Contents

Save PDF