If the lock catch securing the pump to the filter body breaks (indicated
by the red arrow).
Attach the pump to the filter body, securing it in place using a screw,
screwing the latter in the slot (indicated by the green arrow).
Size of the screw 3.5x19 Code 5024 79 51-00/2
23.5.2.2 Tub drain pipe
Set down the appliance in a horizontal position on a protected surface
in order not to damage the unit.
Loosen the screws to slacken the two clamps and remove the pipe.
Tub drain pipe.
23.5.3 Shock absorbers
Set down the appliance in a horizontal position on a protected surface
in order not to damage the unit.
The operations described here are valid for both shock absorbers.
Remove the pin that holds the shock absorber to the welded tub.
Loosen the screw that fixes it to the crosspiece.