Alarm
Alarm Description
Code
Incongruence between
E97
selector and cycles
configuration
FCV_MB protocol incong.
E98
Error
User Interface Configuration
E9C
fault
E9E
UI touch fault
EA1
DSP system failure
EA6
DSP door open failure
EB1
Power supply frequency out
(EH1)
of limits
EB2
Power supply voltage too
(EH2)
high
EB3
Power supply voltage too low
(EH3)
EBD
Heater WD relay
(EHD)
sensing alarm
EBE
FCV Relay failure
(EHE)
EC1
Electro valves blocked
Weight sensor
EC2
communication error
Technical Support - DMM
Fault Condition
Incongruence between
Incorrect configuration data
program selector and cycle
Main board defective
configuration
Protocol communication
between FCV and MB not
Main board incompatible with FCV control board
aligned
Configuration wrongly or
Display Board
not received
Touch display not working
Display Board
Wiring or main board defective
Not drum position sensing
DSP sensor failure
during motor activation
Main motor belt broken
Not sufficient number of
Wiring or main board defective
tachometer impulses
Main motor belt broken
during motor activation
Lid open
Power supply period
lower/higher than
Wrong or disturbed Power Supply line. Main board defective
configured values
MAIN_V sensing input
voltage value greater than
Wrong or disturbed Power Supply line. Main board defective
configured value
MAIN_V sensing input
voltage value lower than
Wrong or disturbed Power Supply line. Main board defective
configured value
Wrong input signal to
Main board defective
microprocessor
Incongruence between
FCV Relay defective
safeties relay sensing and
FCV sensing circuit defective
FCV relay status
Wiring or main board defective
Flow meter running with
Electro valves defective/blocked
electro valves switched
Main board defective
OFF
Communication problem
Wiring defective
between
Weight Sensor defective
Weight sensor and MB
MB defective
Possible Fault
69/124
Machine Action/Status
Reset Key
Cycle blocked
RESET
Cycle blocked
OFF/ON
ON/OFF
No actions
START
RESET
No actions
OFF/ON
Skip of the drum positioning
START
phase
RESET
START
Cycle paused
RESET
Wait for nominal power supply
OFF/ON
conditions
Wait for nominal power supply
OFF/ON
conditions
Wait for nominal power supply
OFF/ON
conditions
Cycle blocked with door
RESET
locked
Safety Drain cycle activation,
stop of the cycle with door
RESET
opened
Cycle blocked
Water drain up to anti-boil
level or max. 5 minutes with
RESET
door locked. When O.L.
blocked drain pump ON/OFF
for 5/5 minutes continuously
START
No actions
RESET
599 75 58-67 Rev. 04