Status Leds - Paradyne Hotwire 5446 Installation Instructions Manual

Rtu customer premises
Hide thumbs Also See for Hotwire 5446:
Table of Contents

Advertisement

Power-On
When power is applied, the RTU performs self-diagnostics and the PWR LED is on. The
self-diagnostics includes a power-on self-test. During the power-on self-test, all of the
LEDs turn on for one second.
5446
TM
Refer to Troubleshooting, page 14, for LED indications requiring action.

Status LEDs

All of the LEDs turn on and off during the power-on self-test. After a successful self-test,
the LEDs should appear as indicated in BOLD in the Condition column below.
LED
Condition Status
PWR
ON
ALM
OFF
ON
TST
OFF
ON
DSL
Fast
blinking
Slow
blinking
ON
OFF
ETHERNET ON
OFF
Power – green
Alarm – red
Test – yellow
Digital Subscriber Line – green
PWR
ALM
TST
RTU has power.
No active alarms.
An alarm condition exists.
No active tests.
The TST LED is on during the power-on self-test and
during a test initiated by the NSP.
RTU is establishing the active DSL link. The LED blinks
on and off about five times per second.
The DSL link is up and the RTU is establishing the active
PPP (Point-to-Point protocol) link. The LED blinks on and
off every two seconds.
The DSL/PPP link is ready to transmit and receive data.
The DSL link has not been established.
The Ethernet 10BaseT connection to the Ethernet hub or
PC is active.
No Ethernet 10BaseT device is detected.
13
Ethernet Link – green
DSL
ETHERNET
97-15317

Advertisement

Table of Contents
loading