Burner And Nozzle Specifications - Hotpoint PK 644DGH X /HA Operating Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 11
Connecting a flexible jointless stainless steel pipe to a
GB
threaded attachment
The gas supply pipe fitting is a threaded 1/2 gas
cylindrical male attachment.
These pipes must be installed so that they are never
longer than 2000 mm when fully extended. Once
connection has been carried out, make sure that the
flexible metal pipe does not touch any moving parts and
is not compressed.
! Only use pipes and seals that comply with current
national regulations.

Burner and nozzle specifications

Table 1
Burner
Fast (R)
Semi Fast (S)
Auxiliary (A)
Supply pressures
*
At 15°C and 1013 mbar-dry gas
Natural P.C.S. = 37.78 MJ/m³
S
S
A
PK 644 D GH X/HA
PKQ 644 D GH /HA
14
Diameter
Thermal Power
(mm)
kW (p.c.s.*)
Nomin.
Reduc.
157
3.00
1.00
132
1.90
0.80
110
1.00
0.50
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
S
R
A
PK 755 D GH X/HA
PKQ 755 D GH /HA
Checking the tightness of the connection
! When the installation process is complete, check the
pipe fittings for leaks using a soapy solution. Never use a
flame.
• Adjusting the burners' primary air :
Does not require adjusting.
! Should the gas pressure used be different (or vary
slightly) from the recommended pressure, a suitable
pressure regulator must be fitted to the inlet pipe (in order
to comply with current national regulations).
Naturale Gas
Nozzle
Flow*
1/100
l/h
(mm)
125
286
100
157
72
95
20
17
25
S
R
A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pkq 644dgh /haPk 755dgh x/haPkq 755dgh /ha

Table of Contents