Reconnect the Pump

1. Screw the connecting rod adapter (11*) to the motor
shaft.
2. Screw the tie rods (8†) into the motor (4†). Using a
wrench on the tie rod flats, torque to 50-60 ft-lb
(68-81 N•m).
3A7945A
3. Make sure the coupling nut (13†) and coupling
collars (12*) are in place on the rod.
To prevent injury from crushing or pinching, always
use at least two people when lifting, moving, or
connecting the pump. When connecting the pump, be
sure to securely brace the pump, or have two people
hold it while another person connects it.
4. Use at least two people to hold the pump (9†) while
another person reconnects it to the motor. Position
the pump as shown below. Place the pump on the
tie rods (8†).
NOTE: When reconnecting the pump (9†) to the motor
(4†), be sure to match the relative position of the pump's
disinfectant outlet to the motor.