Table 34 — 19XR Waterbox Cover Weights, Two-Stage Compressor Frame 6
WATERBOX DESCRIPTION
Dished Head, 150 psig
MWB End Cover, 150 psig
MWB End Cover (ASME), 300 psig
Dished Head, 150 psig
Dished Head (Return Cover), 150 psig
MWB End Cover, 150 psig
MWB End Cover (Return Cover), 150 psig
MWB End Cover (ASME), 300 psig
MWB End Cover (ASME) (Return Cover), 300 psig
Dished Head, 150 psig
MWB End Cover, 150 psig
MWB End Cover (ASME), 300 psig
NOTE(S):
a. Consult factory for 1 and 3 pass data.
b. Weights for dished head cover and MWB end cover 150 psig (1034 kPa) are included in the heat exchanger weights shown in the heat exchanger weight tables.
LEGEND
ASME —
American Society of Mechanical Engineers
MWB —
Marine Waterbox
Table 35 — 19XR Waterbox Cover Weights, Two-Stage Compressor Frame 6
WATERBOX DESCRIPTION
Dished Head, 150 psig
MWB, 150 psig
MWB (ASME), 300 psig
Dished Head, 150 psig
Dished Head (Return Cover),
150 psig
MWB 150 psig
MWB (Return), 150 psig
MWB (ASME), 300 psig
MWB Return Cover (ASME),
300 psig
Dished Head, 150 psig
MWB End Cover, 150 psig
MWB End Cover (ASME),
300 psig
NOTE(S):
a. Consult factory for 1 and 3 pass data.
b. Weights for dished head cover and MWB end cover 150 psig (1034 kPa) are included in the heat exchanger weights shown in the heat exchanger weight tables.
LEGEND
ASME —
American Society of Mechanical Engineers
MWB —
Marine Waterbox
Cooler Frame A
PASSES
Condenser Frame A and B
ENGLISH (LB)
CONDENSER
PASSES
FRAME A
STANDARD
FLANGED STANDARD
NOZZLES
1
895
1060
1
859
859
1
2117
2117
2
981
1179
2
824
824
2
907
907
2
824
824
2
2117
2117
2
2117
2117
3
1067
1157
3
942
942
3
2117
2177
a,b
ENGLISH (LB)
COOLER
FRAME A
STANDARD
NOZZLES
1
1006
1
976
1
2460
2
1140
2
976
2
1068
2
976
2
2460
2
2460
3
1048
3
1030
3
2460
a,b
FRAME B
FLANGED STANDARD
NOZZLES
1006
1171
1075
1075
2744
2744
1140
1400
976
976
1075
1075
976
976
2744
2744
2744
2744
1050
1140
1020
1020
2744
2744
75
METRIC (KG)
COOLER
FRAME A
STANDARD
FLANGED
NOZZLES
1171
456
976
443
2460
1116
1336
517
976
443
1068
484
976
443
2460
1116
2460
1116
1112
475
1030
467
2460
1116
METRIC (KG)
CONDENSER
FRAME A
FLANGED STANDARD
NOZZLES
NOZZLES
406
481
390
390
960
960
1292
445
535
374
374
411
411
374
411
960
1083
1440
960
960
1245
484
525
427
427
960
987
1245
FLANGED
531
443
1116
606
443
484
443
1116
1116
504
467
1116
FRAME B
FLANGED
473
547
488
488
1292
574
633
481
481
630
630
488
488
1440
1245
476
517
463
463
1245