Recommissioning After Standstill - Bosch rexroth A36VM Instruction Manual

Axial piston variable motor
Table of Contents

Advertisement

▶ After the running-in phase, have a hydraulic fluid sample analyzed for the required
cleanliness level.
▶ Change the hydraulic fluid if the required cleanliness level is not reached.
If a laboratory test is not carried out after the running-in phase, it is
recommended to change the hydraulic fluid.
8�3 Recommissioning after standstill
Depending on the installation conditions and ambient conditions, changes may occur
in the hydraulic system which make recommissioning necessary.
The following criteria may make recommissioning necessary:
• Air and/or water in the hydraulic system
• Old hydraulic fluid
• Other contamination
▶ Before recommissioning, proceed as described in chapter 8.1
"Initial commissioning" on page 38.
Commissioning | A36VM
RE 91650-01-B/2021-07-19, Bosch Rexroth AG