Storing The Axial Piston Unit - Bosch rexroth A36VM Instruction Manual

Axial piston variable motor
Table of Contents

Advertisement

24/54
A36VM | Transport and storage
Requirement
After delivery
Bosch Rexroth AG, RE 91650-01-B/2021-07-19
6�2 Storing the axial piston unit
• Storage areas should be free of corrosive materials and gases.
• To prevent damage to the seals, do not operate ozone-forming equipment
(e.g. mercury-vapor lamps, high-voltage equipment, electric motors, sources of
electrical sparks or electrical discharge) in storage areas.
• Storage areas should be dry.
Recommended relative humidity ≤ 60%.
• Ideal bearing temperature: +5 °C to +20 °C.
• Minimum storage temperature: −50 °C.
• Maximum storage temperature: +60 °C.
• Keep out of direct sunlight.
• Do not stack axial piston units and store them in a shock-proof manner.
• Do not store the axial piston unit on the drive shaft or assembled parts,
e.g. sensors or valves.
• For further storage conditions, see Table 7.
▶ Check the axial piston unit monthly to ensure professional storage.
The axial piston units come in corrosion protection packaging
(corrosion protection film) provided at the factory.
Table 7 lists the maximum permissible storage times for an unpackaged
axial piston unit as per data sheet 90312.
Table 7: Storage time with factory corrosion protection
Storage conditions
Closed, dry room, uniform
temperature between +5 °C
and +20 °C. Undamaged
and closed corrosion
protection film.
The warranty will be voided if the requirements and storage conditions are not
observed or after expiration of the max. storage time (see Table 7).
How to proceed once the max. storage time elapses:
1� Check the entire axial piston unit for damage and corrosion prior to installation.
2� Perform a test run to check the axial piston unit for proper functioning and
leak-tightness.
3� If storage time exceeds 24 months, replace the shaft seal.
Once the max. storage time has elapsed, we recommend that you have the
axial piston unit checked by your Bosch Rexroth service partner.
Standard corrosion
protection
Maximum 12 months
Long-term corrosion
protection (optional)
Maximum 24 months