▶ To prevent the transmission of structure-borne noise, use elastic elements
to decouple all connecting lines from all vibration-capable components
(e.g. reservoir, frame parts).
▶ Make sure that the drain line and return line flow into the reservoir below the
minimum fluid level under all operating conditions. This prevents foaming.
▶ Make sure that the working environment at the installation site is completely
free of dust and foreign substances. The axial piston unit should be clean when
installed. Contamination of the hydraulic fluid can considerably affect the
function and service life of the axial piston unit.
▶ Use fiber-free cleaning cloth.
▶ Use suitable, mild cleaning agents to remove lubricants and other heavy
contamination. Do not allow cleaning agents to enter into the hydraulic system.
Installation | A36VM
RE 91650-01-B/2021-07-19, Bosch Rexroth AG
27/54