Bosch rexroth A36VM Instruction Manual page 35

Axial piston variable motor
Table of Contents

Advertisement

Fig� 11: Port overview A36VM with EP1, EP2 control, working ports on opposing sides
Table 10: Ports A36VM
Ports
A, B
T
T
M
1)
2)
3)
4)
Tightening torques
The following tightening torques apply:
• Fittings:
• Female threads in the axial piston unit:
• Threaded plugs:
• Mounting bolts:
T
(port plate 2)
1)
Working port
Drain port
1
Drain port
2
Control pressure measuring port
1
The measuring system and thread size can be found in the installation drawing.
Depending on the application, momentary pressure peaks can occur. Keep this in mind when
selecting measuring devices and fittings.
O = Must be connected (plugged on delivery)
X = Plugged (in normal operation)
Depending on the installation position, T
"Installation position" on page 28)
Observe the manufacturer's specifications regarding the tightening torques of the
fittings used.
The max. permissible tightening torques M
female threads and should not be exceeded. For values, see Table 11.
For the metallic threaded plugs supplied with the axial piston unit, the required
tightening torques of threaded plugs M
For mounting bolts with metric ISO threads according to DIN 13 and/or ASME
B1.1 threads, we recommend checking the tightening torque in individual cases
in accordance with VDI 2230.
1
M
1
B
or T
must be connected (see chapter 7.3
1
2
are the maximum values for the
G max
apply. For values, see Table 11.
V
RE 91650-01-B/2021-07-19, Bosch Rexroth AG
Installation | A36VM
T
1
T
2
A
p
[bar]
2)
State
max
530
3
3
530
35/54
3)
O
X
4)
O
4)
X

Advertisement

Table of Contents
loading