Download Print this page

Meccanica Benassi FOX 110-4WD User And Maintenance Manual page 25

Advertisement

Page 25 of 36 
 
5) PETROL TANK: Does it contain the right type of petrol? See Chap. 7b for all specifications. Also, is the tank
cap well tightened? Is there any leak on the supply hose?
6) ENGINE FLYWHEEL COVER: Remove all debris from the area surrounding the engine and, more importantly,
from the area above the flywheel cover on the side.
7) ROTOR BRAKE CHECK: before starting to work, from the operator position and with the engine on,
engage the rotor, disengage it after few moments, check that the rotor stops completely within 7 seconds.
8) INTEGRITY CHECK on frame and protections: inspect all the frame main hoses, soldered attachments,
floor, rotor casing, shock protection and front bumper. Also, check all protection metal covers. Before each
use, perform an inspection round on the machine. Report immediately the presence of cracks and DO NOT
USE THE MACHINE. Check the integrity of all protective skirts (or chains) placed on the rotor casing front
and back. For the FOX 110-4WD tractor, check the presence and integrity of the lower limbs protection
(part 16 in Chap. 4a): if the protection is absent, it is forbidden to use the machine.
9) PICTOGRAMS CHECK: replace the labels mentioned in Chap. 2a if they are faded, missing or illegible. Ask
for replacement copies to your usual retailer and attach them again in their position.
10) HYDROSTATIC FAN AND REAR AREA INSPECTION: check that the entire surface of the rear hydrostatic
transmission is free from dust or debris. Check that the fan is intact and free to rotate, so to cool down the
transmission below it. In dusty environments, repeat the debris blowing/cleaning operations several times a
day.
11) CHECK THE LEVEL OF THE HYDROSTATIC OIL: inside the external tank, as described in Chap. 7b.
12) BATTERY: In case of difficult start-up, check that the battery has a voltage of at least 12V.
7d – CHECKS AND MAINTENANCE OPERATIONS TO BE CARRIED OUT
 
While the checks described in the previous paragraph must be carried out by the operator, the following
maintenance operations, scheduled at regular intervals, must be performed by a
authorised workshop. According to the type of use, establish the regularity of service checks together with
your usual retailer.
Moreover, please remember that the hour meter of this machine indicates the actual machine running
hours and cannot be reset, nor it sends warning messages or deadline reminders. Report the interventions
Service Sheet of CHAP. 11
carried out on the
Every 50 
- Engine oil full replacement => see
- Complete replacement of all blades and their fixing bolts.
- Engine oil filter replacement => see
- Grease the rotor support bearings: see explanation in the following paragraphs.
- Belt check and adjustment, contact Meccanica Benassi for further details.
- Rotor brake check and adjustment, if its stop time became higher than 7 seconds from the moment the
PTO lever is released.
- Check, greasing, possible adjustment of pedal control elements, steering wheel tie rods, wired control
elements.
- Check of the oil level in the bevel gearbox, see explanation in the following paragraphs.
- Check and possible tightening of all the machine bolts.
Every 100 
 
REGULAR INTERVALS
.
Briggs & Stratton
manual.
Briggs & Stratton
manual.
35451480EN ‐ FOX 110‐4WD and FOX 95‐4WD User and Maintenance Manual 
AT
Meccanica Benassi

Advertisement

loading

This manual is also suitable for:

Fox seriesFox 95-4wd