2.8 EXIT se ngs

DISPLAY READOUT
3 Technical Specifica ons
Inputs
Outputs
Input frequency range (EU*)
Output frequency range (EU*)
LTE protec on
Input level
VHF/UHF Output power (60dB/IM3)
VHF/UHF Output power (36dB/IM3)
VHF/UHF Output power with 1 MUX
VHF/UHF Output power with 6 MUX
VHF/UHF Output power with 15 MUX
VHF/UHF Output power with 32 MUX
Add channels
Number of channels
Conversion
EN
To avoid unauthorized people changing the se ngs, the TMB
1700 can be locked with a security code.
Select LOCK and SET LOCK CODE.
When the lock code is set, the device will shut down.
When you restart the device, you will now have to enter the
correct lock code.
Remark: If you forgot the lock code, you can always use the
value 50. This master code is fixed and cannot be changed.
If you do not want to work with a lock code, go to EXIT and
tap NO LOCK.
TRIAX TMB 1700
-
1 FM/VHF/UHF & 2 VHF/UHF
-
1 main (FM-VHF-S-UHF)
MHz
FM: 88 - 108
VHF:174 - 240
MHz
UHF: 470 - 694
MHz
MHz
88 - 862
MHz
694 (5G)
dBµV
FM: 47 - 109
VHF: 37** - 109
dBµV
UHF: 37** - 109
dBµV
dBµV
114
dBµV
125
dBµV
108
dBµV
108
dBµV
105
dBµV
102
-
Per 1, 2, 3, 4, 5 or 6 MUXes
-
More than 50 (32 filters)
-
Yes (from any VHF-UHF channel
to any VHF-S-UHF channel)
10