2.7 ADVANCED se ngs

DISPLAY READOUT
Note: You can convert any single input Channel, to any output Channel posi on (including output S-channels). But
you can only convert a group of input channels to a group of output channels with the same channel spacing.
Some examples:
21:23
 31:33
07:07
 S15:15
07:07
 S35:35
(Even though channel spacing and bandwidth is different)
07:08
 S35:36
The language of the TMB 1700 can be set to English, Italian,
Spanish or French.
Tap REGION to check to which region/country the TMB 1700
is set. To change the region/country, a hard reset is required
(see instruc ons above (cfr. REGION/COUNTRY SETTINGS).
Define DC VOLTAGE for the inputs, choose between 12V or
24V. This is a global se ng for all inputs, each input can then
be switched between OFF or this value.
(cfr. STEP 2). All countries are set by default on 24V, except UK
which is set by default on 12V.
The filter bandwidth can be changed from -2000 kHz to 0 kHZ
in steps of 250 kHz.
This allows you to op mize the bandwidth of your filter.
For instance, a European 8 MHz channel can be changed from
6 to 8 MHz. The default se ng is -750 kHz, which is an
op mal se ng in 95% of the cases.
S-Band channels can be ac vated in Advanced Mode. By
default, they are not ac vated.
See NOTE below for more explana on.
Tap FW VERSION to check the firmware version of the device.
Tap SERIAL NUMBER to check the serial number of the
device.
Can be converted because groups of channels have same channel spacing
Can be converted because single channel conversion
Can be converted because single channel conversion
Can't be converted because groups of channels have different channel spacing
9