Endress+Hauser Proline 300 Brief Operating Instructions
Endress+Hauser Proline 300 Brief Operating Instructions

Endress+Hauser Proline 300 Brief Operating Instructions

Advertisement

Quick Links

KA01517D/06/EN/01.22-00
71589704
2024-01-08
Products
Brief Operating Instructions
Proline 300
Transmitter with Coriolis sensor
PROFINET with Ethernet-APL
These instructions are Brief Operating Instructions; they are
not a substitute for the Operating Instructions pertaining to
the device.
Brief Operating Instructions part 2 of 2: Transmitter
Contain information about the transmitter.
Brief Operating Instructions part 1 of 2: Sensor →  3
Solutions
Services

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Proline 300 and is the answer not in the manual?

Questions and answers

Summary of Contents for Endress+Hauser Proline 300

  • Page 1 Solutions Services KA01517D/06/EN/01.22-00 71589704 2024-01-08 Brief Operating Instructions Proline 300 Transmitter with Coriolis sensor PROFINET with Ethernet-APL These instructions are Brief Operating Instructions; they are not a substitute for the Operating Instructions pertaining to the device. Brief Operating Instructions part 2 of 2: Transmitter Contain information about the transmitter.
  • Page 2 Proline 300 PROFINET with Ethernet-APL Order code: XXXXX-XXXXXX Ser. no.: XXXXXXXXXXXX Ext. ord. cd.: XXX.XXXX.XX Serial number www.endress.com/deviceviewer Endress+Hauser Operations App A0023555 Endress+Hauser...
  • Page 3 Proline 300 PROFINET with Ethernet-APL Brief Operating Instructions for flowmeter Brief Operating Instructions for flowmeter The device consists of a transmitter and a sensor. The process of commissioning these two components is described in two separate manuals that together form the Brief Operating Instructions for the flowmeter: •...
  • Page 4: Table Of Contents

    Table of contents Proline 300 PROFINET with Ethernet-APL Table of contents About this document ............. . 5 Symbols used .
  • Page 5: About This Document

    Proline 300 PROFINET with Ethernet-APL About this document About this document Symbols used 1.1.1 Safety symbols DANGER This symbol alerts you to a dangerous situation. Failure to avoid this situation will result in serious or fatal injury. WARNING This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in serious or fatal injury.
  • Page 6 About this document Proline 300 PROFINET with Ethernet-APL Symbol Meaning Potential equalization connection (PE: protective earth) Ground terminals that must be connected to ground prior to establishing any other connections. The ground terminals are located on the interior and exterior of the device: •...
  • Page 7: Safety Instructions

    Proline 300 PROFINET with Ethernet-APL Safety instructions Safety instructions Requirements for the personnel The personnel must fulfill the following requirements for its tasks: ‣ Trained, qualified specialists must have a relevant qualification for this specific function and task. ‣ Are authorized by the plant owner/operator.
  • Page 8: Workplace Safety

    Verification for borderline cases: ‣ For special fluids and fluids for cleaning, Endress+Hauser is glad to provide assistance in verifying the corrosion resistance of fluid-wetted materials, but does not accept any warranty or liability as minute changes in the temperature, concentration or level of contamination in the process can alter the corrosion resistance properties.
  • Page 9: Security

    (Statutory Instruments). These are listed in the UKCA Declaration of Conformity along with the designated standards. By selecting the order option for the UKCA marking Endress+Hauser confirms the successful testing and assessment of the device by affixing to it the UKCA mark.
  • Page 10: Product Description

    Product description Proline 300 PROFINET with Ethernet-APL Product description The device consists of a Proline 300 transmitter and a Proline Promass or Cubemass Coriolis sensor. The device is available as a compact version: The transmitter and sensor form a mechanical unit.
  • Page 11: Mounting

    Proline 300 PROFINET with Ethernet-APL Mounting Mounting For detailed information about mounting the sensor, see the Sensor Brief Operating Instructions →  3 Turning the transmitter housing To provide easier access to the connection compartment or display module, the transmitter housing can be turned.
  • Page 12 Mounting Proline 300 PROFINET with Ethernet-APL 4 mm 7 Nm (5.2 lbf ) A0043150  2 Ex housing Loosen the fixing screws. Turn the housing to the desired position. Tighten the securing screws. Endress+Hauser...
  • Page 13: Turning The Display Module

    Proline 300 PROFINET with Ethernet-APL Mounting Turning the display module The display module can be turned to optimize display readability and operability. – – – 3 mm A0030035 Depending on the device version: Loosen the securing clamp of the connection compartment cover.
  • Page 14: Cover Lock

    Mounting Proline 300 PROFINET with Ethernet-APL Cover lock NOTICE Order code "Housing", option L "Cast, stainless": The covers of the transmitter housing are provided with a borehole to lock the cover. The cover can be locked using screws and a chain or cable provided by the customer on site.
  • Page 15: Electrical Connection

    Proline 300 PROFINET with Ethernet-APL Electrical connection Electrical connection WARNING Live parts! Incorrect work performed on the electrical connections can result in an electric shock. ‣ Set up a disconnecting device (switch or power-circuit breaker) to easily disconnect the device from the supply voltage.
  • Page 16 Electrical connection Proline 300 PROFINET with Ethernet-APL Signal cable PROFINET with Ethernet-APL The reference cable type for APL segments is fieldbus cable type A, MAU type 1 and 3 (specified in IEC 61158-2). This cable meets the requirements for intrinsically safe applications according to IEC TS 60079-47 and can also be used in non-intrinsically safe applications.
  • Page 17 Proline 300 PROFINET with Ethernet-APL Electrical connection Available cable length 5 m (15 ft)/10 m (35 ft)/20 m (65 ft)/30 m (100 ft) Operating temperature When mounted in a fixed position: –50 to +105 °C (–58 to +221 °F); when cable can move freely: –25 to +105 °C (–13 to +221 °F)
  • Page 18: Connecting The Measuring Device

    Electrical connection Proline 300 PROFINET with Ethernet-APL 5.2.3 Terminal assignment Transmitter: supply voltage, input/outputs The terminal assignment of the inputs and outputs depends on the individual order version of the device. The device-specific terminal assignment is documented on an adhesive label in the terminal cover.
  • Page 19 Proline 300 PROFINET with Ethernet-APL Electrical connection 5.3.1 Connecting the transmitter A0026781 Terminal connection for supply voltage Terminal connection for signal transmission, input/output Terminal connection for signal transmission, input/output or terminal connection for network connection via service interface (CDI-RJ45); optional: connection for external WLAN antenna or...
  • Page 20 Electrical connection Proline 300 PROFINET with Ethernet-APL N ic N ic t e r t e r e r g ö f f e r g ö f f iz e iz e t e n t e n r ir...
  • Page 21 Proline 300 PROFINET with Ethernet-APL Electrical connection Connecting the supply voltage and additional inputs/outputs 10 (0.4) mm (in) – A0051128 Push the cable through the cable entry. To ensure tight sealing, do not remove the sealing ring from the cable entry.
  • Page 22 Electrical connection Proline 300 PROFINET with Ethernet-APL Removing a cable 3 (0.12) A0029598  3 Engineering unit mm (in) To remove a cable from the terminal, use a flat-blade screwdriver to push the slot between the two terminal holes while simultaneously pulling the cable end out of the terminal.
  • Page 23: Hardware Settings

    Proline 300 PROFINET with Ethernet-APL Electrical connection 5.3.2 Connecting the remote display and operating module DKX001 The remote display and operating module DKX001 is available as an optional extra. • The remote display and operating module DKX001 is only available for the following housing version: order code for "Housing": option A "Aluminum, coated"...
  • Page 24 Electrical connection Proline 300 PROFINET with Ethernet-APL Endress+Hauser Promass Instrument family Transmitter XXXX Serial number of the device The device name currently used is displayed in Setup → Name of station . Setting the device name using the DIP switches The last part of the device name can be set using DIP switches 1-8.
  • Page 25 Proline 300 PROFINET with Ethernet-APL Electrical connection A0034498 ‣ Set the desired device name using the corresponding DIP switches on the I/O electronics module. Setting the device name via the automation system DIP switches 1-8 must all be set to OFF (factory setting) or all be set to ON to be able to set the device name via the automation system.
  • Page 26: Ensuring Potential Equalization

    Electrical connection Proline 300 PROFINET with Ethernet-APL A0034499 ‣ Set DIP switch no. 2 on the I/O electronics module from OFF → ON. Ensuring potential equalization 5.5.1 Requirements For devices intended for use in hazardous locations, please observe the guidelines in the Ex documentation (XA).
  • Page 27: Post-Connection Check

    Proline 300 PROFINET with Ethernet-APL Electrical connection Post-connection check Are cables or the device undamaged (visual inspection)?  Is the protective earthing established correctly? Do the cables used comply with the requirements ?  Do the mounted cables have adequate strain relief? ...
  • Page 28: Operation Options

    Operation options Proline 300 PROFINET with Ethernet-APL Operation options Overview of operation options A0046226 Local operation via display module Computer with web browser (e.g. Internet Explorer) or with operating tool (e.g. FieldCare, SIMATIC PDM) Field Xpert SMT70 Mobile handheld terminal Control system (e.g.
  • Page 29: Structure And Function Of The Operating Menu

    Proline 300 PROFINET with Ethernet-APL Operation options Structure and function of the operating menu 6.2.1 Structure of the operating menu Operating menu for operators and maintenances Language Operation task-oriented Setup Diagnostics Operating menu for experts Expert function-oriented A0014058-EN  4 Schematic structure of the operating menu 6.2.2...
  • Page 30: Access To The Operating Menu Via The Local Display

    Operation options Proline 300 PROFINET with Ethernet-APL Access to the operating menu via the local display X X X X X X 19.184 mA 12.5 X X X X X X Language 20.50 Ã English Deutsch Español Français Xxxxxxx A B C D E F G H I J K M N O P Q R S T U V W +0.000 Xx...
  • Page 31 Proline 300 PROFINET with Ethernet-APL Operation options 6.3.1 Operational display Explanatory symbols for the measured value Status area • Depends on the device version, e.g.: The following symbols appear in the status area of the • : Volume flow operational display at the top right: •...
  • Page 32 Operation options Proline 300 PROFINET with Ethernet-APL Numeric editor Confirms selection. Moves the input position one position to the left. Exits the input without applying the changes. Inserts decimal separator at the cursor position. Inserts minus sign at the cursor position.
  • Page 33: Access To The Operating Menu Via The Operating Tool

    Proline 300 PROFINET with Ethernet-APL System integration Keys and meaning Minus/Enter key combination (press the keys simultaneously) With an operational display: • If keypad lock is active: Pressing the key for 3 s deactivates the keypad lock. • If keypad lock is not active: Pressing the key for 3 s opens the context menu including the option for activating the keypad lock.
  • Page 34: Setting The Operating Language

    Commissioning Proline 300 PROFINET with Ethernet-APL Setting the operating language Factory setting: English or ordered local language X X X X X X X 20.50 Main menu 0104-1 Display language English Operation Setup Display language 0104-1 English à Deutsch Español Français...
  • Page 35: Protecting Settings From Unauthorized Access

    Proline 300 PROFINET with Ethernet-APL Commissioning Example: Available submenus, wizards Meaning Partially filled pipe detection Configuration of the detection of partially filled and empty pipes Advanced setup Additional parameters for configuration: • Calculated process variables • Sensor adjustment • Totalizer •...
  • Page 36: Diagnostic Information

    Diagnostic information Proline 300 PROFINET with Ethernet-APL Diagnostic information Faults detected by the self-monitoring system of the measuring device are displayed as a diagnostic message in alternation with the operational display. The message about remedial measures can be called up from the diagnostic message, and contains important information on the fault.
  • Page 40 *71589704* 71589704 www.addresses.endress.com...