Products Solutions Services KA01227D/06/EN/02.18 71399858 2018-08-01 Brief Operating Instructions Proline 300 PROFIBUS PA Transmitter with Coriolis sensor These instructions are Brief Operating Instructions; they are not a substitute for the Operating Instructions pertaining to the device. Transmitter Brief Operating Instructions Contain information about the transmitter.
Page 2
Proline 300 PROFIBUS PA Order code: XXXXX-XXXXXX Ser. no.: XXXXXXXXXXXX Ext. ord. cd.: XXX.XXXX.XX Serial number www.endress.com/deviceviewer Endress+Hauser Operations App A0023555 Endress+Hauser...
Page 3
These Brief Operating Instructions are the Transmitter Brief Operating Instructions. The "Sensor Brief Operating Instructions" are available via: • Internet: www.endress.com/deviceviewer • Smart phone/tablet: Endress+Hauser Operations App Detailed information about the device can be found in the Operating Instructions and the other documentation: • Internet: www.endress.com/deviceviewer...
Proline 300 PROFIBUS PA Document information Document information Symbols used 1.1.1 Safety symbols Symbol Meaning DANGER! DANGER This symbol alerts you to a dangerous situation. Failure to avoid this situation will result in serious or fatal injury. WARNING! This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in WARNING serious or fatal injury.
Page 6
Document information Proline 300 PROFIBUS PA Symbol Meaning Protective Earth (PE) A terminal which must be connected to ground prior to establishing any other connections. The ground terminals are situated inside and outside the device: • Inner ground terminal: Connects the protectiv earth to the mains supply.
Proline 300 PROFIBUS PA Basic safety instructions Basic safety instructions Requirements for the personnel The personnel must fulfill the following requirements for its tasks: ‣ Trained, qualified specialists must have a relevant qualification for this specific function and task. ‣...
Verification for borderline cases: ‣ For special fluids and fluids for cleaning, Endress+Hauser is glad to provide assistance in verifying the corrosion resistance of fluid-wetted materials, but does not accept any warranty or liability as minute changes in the temperature, concentration or level of contamination in the process can alter the corrosion resistance properties.
It meets general safety standards and legal requirements. It also complies with the EU directives listed in the device-specific EU Declaration of Conformity. Endress+Hauser confirms this by affixing the CE mark to the device. IT security Our warranty is valid only if the device is installed and used as described in the Operating Instructions.
Product description Proline 300 PROFIBUS PA Product description The device consists of a Proline 300 transmitter and an electromagnetic Proline Promag sensor. The device consists of a Proline 300 transmitter and a Proline Promass or Cubemass Coriolis sensor. The device is available as a compact version: The transmitter and sensor form a mechanical unit.
Page 11
Proline 300 PROFIBUS PA Product description N ic t e r e r g ö f f iz e t e n s io r ir I/ O – A0029586 Connection compartment cover Display module Transmitter housing Electronics compartment cover Sensor Use of the device with the remote display and operating module DKX001 →...
Installation Proline 300 PROFIBUS PA Installation For detailed information about mounting the sensor, see the Sensor Brief Operating Instructions → 3 Turning the transmitter housing To provide easier access to the connection compartment or display module, the transmitter housing can be turned.
Proline 300 PROFIBUS PA Installation Turning the display module The display module can be turned to optimize display readability and operability. – – – 3 mm A0030035 Depending on the device version: Loosen the securing clamp of the connection compartment cover.
Installation Proline 300 PROFIBUS PA Cover locking NOTICE Order code for "Housing", option L "Cast, stainless": The covers of the transmitter housing are provided with a borehole to lock the cover. The cover can be locked using screws and a chain or cable provided by the customer.
Proline 300 PROFIBUS PA Electrical connection Electrical connection NOTICE The measuring device does not have an internal circuit breaker. ‣ For this reason, assign the measuring device a switch or power-circuit breaker so that the power supply line can be easily disconnected from the mains.
Page 16
Electrical connection Proline 300 PROFIBUS PA Signal cable PROFIBUS PA Twisted, shielded two-wire cable. Cable type A is recommended . For further information on planning and installing PROFIBUS networks see: • Operating Instructions "PROFIBUS DP/PA: Guidelines for planning and commissioning"...
Page 17
Proline 300 PROFIBUS PA Electrical connection Standard cable - customer-specific cable No cable is supplied, and it must be provided by the customer (up to max. 300 m (1 000 ft)) for the following order option: Order code for DKX001: Order code 040 for "Cable", option 1 "None, provided by customer, max 300 m"...
Page 19
Proline 300 PROFIBUS PA Electrical connection 5.2.1 Connecting the transmitter A0026781 Terminal connection for supply voltage Terminal connection for signal transmission, input/output Terminal connection for signal transmission, input/output or terminal connection for network connection via service interface (CDI-RJ45); optional: connection for external WLAN antenna or...
Page 20
Electrical connection Proline 300 PROFIBUS PA N ic N ic t e r t e r e r g ö f f e r g ö f f iz e iz e t e n t e n r ir...
Page 21
Proline 300 PROFIBUS PA Electrical connection 22 mm 24 mm – A0029816 10. Connect the cable in accordance with the terminal assignment . Signal cable terminal assignment: The device-specific terminal assignment is documented on an adhesive label in the terminal cover.
Page 22
Electrical connection Proline 300 PROFIBUS PA Removing a cable 3 (0.12) A0029598 1 Engineering unit mm (in) To remove a cable from the terminal, use a flat-blade screwdriver to push the slot between the two terminal holes while simultaneously pulling the cable end out of the terminal.
Proline 300 PROFIBUS PA Electrical connection 5.2.2 Connecting the remote display and operating module DKX001 The remote display and operating module DKX001 is available as an optional extra . • The remote display and operating module DKX001 is only available for the following housing version: order code for "Housing": option A "Aluminum, coated"...
Electrical connection Proline 300 PROFIBUS PA Hardware settings 5.4.1 Setting the device address The address must always be configured for a PROFIBUS DP/PA device. The valid address range is between 1 and 126. In a PROFIBUS DP/PA network, each address can only be assigned once.
Proline 300 PROFIBUS PA Electrical connection Ensuring the degree of protection The measuring device fulfills all the requirements for the IP66/67 degree of protection, Type 4X enclosure. To guarantee IP66/67 degree of protection, Type 4X enclosure, carry out the following steps after the electrical connection: Check that the housing seals are clean and fitted correctly.
Operation options Proline 300 PROFIBUS PA Operation options Overview of operation options A0034513 Local operation via display module Computer with Web browser (e.g. Internet Explorer) or with operating tool (e.g. FieldCare, DeviceCare, AMS Device Manager, SIMATIC PDM) Field Xpert SFX350 or SFX370...
Proline 300 PROFIBUS PA Operation options Structure and function of the operating menu 6.2.1 Structure of the operating menu Operating menu for operators and maintenances Language Operation task-oriented Setup Diagnostics Operating menu for experts Expert function-oriented A0014058-EN 2 Schematic structure of the operating menu 6.2.2...
Operation options Proline 300 PROFIBUS PA Access to the operating menu via the local display X X X X X X 19.184 mA 12.5 X X X X X X Language 20.50 Ã English Deutsch Español Français Xxxxxxx A B C D E F G H I J K M N O P Q R S T U V W +0.000 Xx...
Page 29
Proline 300 PROFIBUS PA Operation options 6.3.1 Operational display Explanatory symbols for the measured value Status area • Depends on the device version, e.g.: The following symbols appear in the status area of the – : Volume flow operational display at the top right: –...
Page 30
Operation options Proline 300 PROFIBUS PA Numeric editor Confirms selection. Moves the input position one position to the left. Exits the input without applying the changes. Inserts decimal separator at the input position. Inserts minus sign at the input position.
Proline 300 PROFIBUS PA System integration Keys and meaning Reduces the contrast (brighter setting). Plus/Enter key combination (press and hold down the keys simultaneously) Increases the contrast (darker setting). Minus/Plus/Enter key combination (press the keys simultaneously) For operational display:Enables or disables the keypad lock.
Commissioning Proline 300 PROFIBUS PA Commissioning Function check Before commissioning the measuring device: ‣ Make sure that the post-installation and post-connection checks have been performed. • "Post-installation check" checklist → 14 • "Post-connection check" checklist → 25 Setting the operating language...
Proline 300 PROFIBUS PA Commissioning Configuring the measuring device The Setup menu with its submenus and guided wizards is used for fast commissioning of the device. They contain all the parameters required for configuration, such as for measurement or communication.
Diagnostic information Proline 300 PROFIBUS PA Diagnostic information Faults detected by the self-monitoring system of the measuring device are displayed as a diagnostic message in alternation with the operational display. The message about remedial measures can be called up from the diagnostic message, and contains important information on the fault.