Negative pressure units with control SRE connect

IoT (Internet of Things) => Units with SRE connect control can be remotely controlled and
monitored with any internet-enabled PC, mobile phone or tablet.
For power regulation, the Negative pressure unit is supplied with a control via a touch
display to measure and regulate the negative pressure and / or the volume flow.
The negative pressure is measured between the black area and a reference point to be
defined (adjacent rooms) and kept at the setpoint by continuous speed control of the electric
fan.
The volume flow is measured in the unit and kept at the setpoint by continuous speed control
of the electric fan.
Manual control is also possible.
A filter sensor monitors the particle concentration in the exhaust air and triggers a visual
and acoustic alarm if a value of approx. 100 particles per litre is permanently exceeded.
A necessary filter change is indicated on the display.
The connect functions are supported as standard in the following countries:
Albania, Algeria, Armenia, Aruba, Australia, Austria, Azerbaijan, Bangladesh, Belarus,
Belgium, Bolivia, Bonaire, Bulgaria, Cambodia, China, Croatia, Curacao, Cyprus, Czech
Republic, Denmark, El Salvador, Estonia, Faroe Islands, Finland, France, French Guyana,
Georgia, Germany, Ghana, Gibraltar, Greece, Guadeloupe, Guyana, Honduras, Hong
Kong, Hungary, Iceland, Indonesia, Ireland, Israel, Italy, Japan, Jersey, Kazakhstan,
Kuwait, Kyrgyzstan, Laos, Latvia, Liechtenstein, Lithuania, Luxembourg, Macau,
Macedonia, Malaysia, Malta, Martinique, Moldova, Mongolia, Montenegro, Nepal,
Netherlands, Netherlands Antilles, New Zealand, Nigeria, Norway, Pakistan, Palestine,
Panama, Papua New Guinea, Philippines, Poland, Portugal, Puerto Rico, Qatar, Romania,
Russia, Saint Eustatius and Saba, Saint Martin (French part), Saint-Barthélemy, Serbia,
Singapore, Slovakia, Slovenia, South Africa, South Korea, Spain, Suriname, Sweden,
Switzerland, Taiwan, Tajikistan, Tanzania, Thailand, Tonga, Trinidad and Tobago, Tunisia,
Turkey, Ukraine, United Kingdom, United States, Uzbekistan, Vietnam, Virgin Islands, U.S.,
Zambia
All other countries not listed on request
Negative pressure unit green dec G 600, G 700
Original operating instructions
Operation
29 from 62
Version 1

Advertisement

Table of Contents
loading

This manual is also suitable for:

G 700

Table of Contents