Page 1
Original instruction manual Negative pressure unit green dec G 600, G 700 G 600 G 700 Language: EN Version: 1 Phone: 02874/9156-0 deconta GmbH Fax: 02874/9156-11 Issue Date: Im Geer 20 E-mail: info@deconta.com 18.03.2024 46419 Isselburg Web: www.deconta.com...
Technical data ........................ 12 Dimensions ......................12 Weights ........................ 12 Performance data ....................12 4.3.1 Negative pressure unit green dec G 600 ..........13 4.3.2 Negative pressure unit green dec G 700 ..........13 Environmental conditions ..................13 Noise emission ..................... 14 4.5.1...
Page 3
8.7.13 Alarms ....................42 8.7.14 Switch off the unit ................... 44 Maintenance ........................45 Loss of warranty claims ..................45 Maintenance ......................45 Negative pressure unit green dec G 600, G 700 3 from 62 Original operating instructions Version 1...
Page 4
Negative pressure unit green dec G 700 .............. 55 12 Circuit diagrams ......................56 12.1 Negative pressure unit green dec G 600 SRE connect ......... 56 12.2 Negative pressure unit green dec G 700 SRE connect ......... 58 13 Storage ........................... 60 13.1...
GmbH Im Geer 20 46419 Isselburg Phone 02874/9156-0 02874/9156-11 E-Mail info@deconta.com Internet www.deconta.com Change index Date Version Change Responsible 21.03.2023 Re-creation Thomas Boland Negative pressure unit green dec G 600, G 700 5 from 62 Original operating instructions Version 1...
When handing over the machine to another person, the operator passes these operating instructions on to that person. Negative pressure unit green dec G 600, G 700 6 from 62 Original operating instructions Version 1...
Description of the possible consequences for humans, animals and the environment that may occur as a result of the hazard. Escape Recommendations for action on how to avoid hazards Negative pressure unit green dec G 600, G 700 7 from 62 Original operating instructions Version 1...
The following table gives an overview of the commandment signs used and their meaning. Symbol Meaning Symbol Meaning Use hearing protection Use protective clothing Wear safety shoes Use head protection Use hand protection Negative pressure unit green dec G 600, G 700 8 from 62 Original operating instructions Version 1...
This section contains information for understanding the machine. General description General description of the product The machine (the Negative pressure unit) was designed and built by deconta GmbH, Im Geer 20, 46419 Isselburg. Negative pressure unit as container unit for filtering asbestos-contaminated room air via a 3-stage filter unit.
▪ Human product: Control panel, touch screen ▪ Product power supply: Electrical power supply 400 V ▪ Product waste: optional connection pipe for contaminated air Negative pressure unit green dec G 600, G 700 10 from 62 Original operating instructions...
The following accessories are optionally available for the machine: 3.7.1 Negative pressure unit green dec G 700 Designation Item no. Figure Discharge flange NW 450 BO20809 Silencer BO25006 Negative pressure unit green dec G 600, G 700 11 from 62 Original operating instructions Version 1...
EMC filter can cause RCD protection devices to respond with instantaneous tripping. We recommend residual current circuit breakers with a delayed tripping (super-resistant). Negative pressure unit green dec G 600, G 700 12 from 62 Original operating instructions Version 1...
Pocket filter HEPA filter according to EN 1822 class H13 Environmental conditions Ambient temperature 0 °C to +45 °C Relative humidity 70 % non-condensing Negative pressure unit green dec G 600, G 700 13 from 62 Original operating instructions Version 1...
Negative pressure unit green dec G 600 Status: Outdoor area, values in dB (A) Power 30 % 40 % 50 % 70 % 100 % Negative pressure unit green dec G 600, G 700 14 from 62 Original operating instructions Version 1...
70 % 100 % Wear hearing protection in the immediate vicinity of the Negative pressure units G 700, at fan power 100 %. Negative pressure unit green dec G 600, G 700 15 from 62 Original operating instructions Version 1...
By attaching a silencer, the sound level can be reduced, taking into account power losses. Status: Outdoor area, values in dB (A) Power 30 % 40 % 50 % 70 % 100 % Negative pressure unit green dec G 600, G 700 16 from 62 Original operating instructions Version 1...
42 Pa Recommended final pressure difference 250 Pa Temperature / Humidity 100°C/100% RF (relative humidity) Filter dimensions (in mm): 610 x 610 x 47 Negative pressure unit green dec G 600, G 700 17 from 62 Original operating instructions Version 1...
Recommended final pressure difference 250 Pa Temperature / Humidity 55°C/100% RF (relative humidity) Filter area 5,1 m² Filter dimensions (in mm): 592 x 592 x 600 Negative pressure unit green dec G 600, G 700 18 from 62 Original operating instructions Version 1...
H13 or H 14 according to EN 1822 70°C/100% RF Temperature / Humidity (relative humidity) Filter dimensions (in mm) 610 x 610 x 292 Handle protection on both sides Negative pressure unit green dec G 600, G 700 19 from 62 Original operating instructions Version 1...
Any other use is not in accordance with the intended use. Range of application The machine is intended for use in the following applications: Range of application ▪ Refurbishments Negative pressure unit green dec G 600, G 700 20 from 62 Original operating instructions Version 1...
▪ Operating the machine in a technically unsound condition, not being aware of safety and hazards and not observing all instructions in the documentation. Negative pressure unit green dec G 600, G 700 21 from 62 Original operating instructions...
Qualified waste Disposer Dispose of machine management company for legally compliant, proper and professional disposal of the machine Negative pressure unit green dec G 600, G 700 22 from 62 Original operating instructions Version 1...
Instruction of persons with regard to protective devices and supplementary protective devices Instruction of persons with regard to residual risks This list is not exhaustive and does not claim to be complete. Negative pressure unit green dec G 600, G 700 23 from 62 Original operating instructions Version 1...
Use gloves. For transport, the unit must be attached to hoists or transported by a forklift truck. Hands can be crushed or scraped during these operations. Negative pressure unit green dec G 600, G 700 24 from 62 Original operating instructions...
Hands can be crushed or scraped during these operations. Crushing hazard: Wear safety shoes to protect against running over limbs. Negative pressure unit green dec G 600, G 700 25 from 62 Original operating instructions Version 1...
Falling of the machine possible due to unintentional change of position when loading and unloading onto / from a means of transport. Negative pressure unit green dec G 600, G 700 26 from 62 Original operating instructions...
The Negative pressure unit is delivered from the factory ready for operation and is intended for immediate commissioning. If there is visible damage, do not operate the unit. Contact deconta GmbH immediately. Please note: In principle, the Negative pressure unit can also...
One person is needed to use the machine. Tools needed No tools are needed to use the machine. Required tools No tools are needed to use the machine. Negative pressure unit green dec G 600, G 700 28 from 62 Original operating instructions Version 1...
Switzerland, Taiwan, Tajikistan, Tanzania, Thailand, Tonga, Trinidad and Tobago, Tunisia, Turkey, Ukraine, United Kingdom, United States, Uzbekistan, Vietnam, Virgin Islands, U.S., Zambia All other countries not listed on request Negative pressure unit green dec G 600, G 700 29 from 62 Original operating instructions Version 1...
▪ at least 1 special character. You will see this page after successful registration. Any number of devices can now be assigned to the user account. Negative pressure unit green dec G 600, G 700 30 from 62 Original operating instructions Version 1...
Tap the "Menu" button. Tap the "Service" button Tap the "deconta connect" button. The page with a QR code and a key underneath is displayed. Negative pressure unit green dec G 600, G 700 31 from 62 Original operating instructions Version 1...
Page 32
Tap on the menu icon and then on "Devices". Tap on the button "SCAN QR CODE (our recommendation) or alternatively on the button "SOFTWARE KEY". Negative pressure unit green dec G 600, G 700 32 from 62 Original operating instructions Version 1...
Page 33
QR code on the device in the field provided and then tap the green button "SUBMIT DEVICE KEY", the device is now registered in your user account. Negative pressure unit green dec G 600, G 700 33 from 62 Original operating instructions Version 1...
8.7.4 Switch on main switch Main switch After initialisation, the unit is ready for operation. The last saved settings are automatically set. Negative pressure unit green dec G 600, G 700 34 from 62 Original operating instructions Version 1...
The display shows the power value in % (Power), the measured negative pressure in Pa, the volume flow in m³/h and the filter pressure in Pa. Negative pressure unit green dec G 600, G 700 35 from 62 Original operating instructions...
By comparing the entered setpoint with the permanently measured current actual value, the speed of the fan is automatically adjusted, i.e. the fan automatically "goes up" or "goes down". Negative pressure unit green dec G 600, G 700 36 from 62 Original operating instructions...
The standby mode is switched on in the menu by tapping the "Standby" button. In the Standby waiting time field, a delay of 0-600 seconds for switching on can be entered. Negative pressure unit green dec G 600, G 700 37 from 62...
The functions and the status of the filter sensors are shown in the display. The measured values of the filter sensors can be displayed graphically via the "Record" button. Negative pressure unit green dec G 600, G 700 38 from 62 Original operating instructions...
Assigning a device to a connect account, see 8.7.1. Maintenance Settings in this menu can only be made by qualified deconta service partners. Negative pressure unit green dec G 600, G 700 39 from 62 Original operating instructions...
Page 40
By tapping the yellow button "Reset factory settings? (reset to factory settings?) the red button "Reset factory settings!" is activated. Tapping this red button resets all settings to factory defaults! Negative pressure unit green dec G 600, G 700 40 from 62 Original operating instructions...
Japanese, Dutch and Portuguese. By tapping the button m³\h the unit can be changed to m³/min. 8.7.12 Device information Display of unit information. Negative pressure unit green dec G 600, G 700 41 from 62 Original operating instructions Version 1...
Alarms are displayed with a red button. After the fault has been eliminated, the alarm must be acknowledged by tapping the respective button, the colour changes to green. Negative pressure unit green dec G 600, G 700 42 from 62 Original operating instructions...
Page 43
Stop dust sensor / Start dust sensor: ▪ Switching the dust sensors on / off. When sensors switched off, particle concentration in the exhaust air is not monitored! Negative pressure unit green dec G 600, G 700 43 from 62 Original operating instructions Version 1...
Switch off the unit To switch off the unit, tap the red "OFF" button. The unit switches off and the mains plug can be pulled out. Negative pressure unit green dec G 600, G 700 44 from 62 Original operating instructions...
Change filters only when the unit is switched off. Only use approved filters. Do not use residual fibre binders on the unit. Pull out the mains plug before opening the housing Negative pressure unit green dec G 600, G 700 45 from 62 Original operating instructions Version 1...
100 Pascal or more, the unit can continue to be operated. If the value drops by less than 100 Pascal, the HEPA filter must be replaced. Negative pressure unit green dec G 600, G 700 46 from 62...
Pull out the mains plug before opening the housing Maintenance work, including changing / removing the filters, may only be carried out by authorised persons wearing suitable protective clothing. Negative pressure unit green dec G 600, G 700 47 from 62 Original operating instructions Version 1...
▪ Remove the pre-filter and dispose of it in accordance with the regulations. ▪ Insert the new filters Pre-filter Change the pocket filter: ▪ Remove prefilter ▪ Open the pocket filter lock Lock Negative pressure unit green dec G 600, G 700 48 from 62 Original operating instructions Version 1...
Page 49
▪ Insert prefilter Change HEPA filter: ▪ Dismantle the filter cassettes for pre-filters and pocket filters by loosening and removing the screws. Screws Filter cassette Negative pressure unit green dec G 600, G 700 49 from 62 Original operating instructions Version 1...
Page 50
▪ Reattach the clamping bars ▪ Fitting filter cassettes for pre-filters and pocket filters The units have only been tested with original deconta HEPA filters. To ensure machine safety, only original deconta filters should be used. If this is not observed, machine safety cannot be guaranteed.
Unit does not Components on the vacuum Have the unit repaired by deconta or work holding device defective a workshop authorised by deconta. Negative pressure unit green dec G 600, G 700 51 from 62 Original operating instructions Version 1...
Double filtration (option) Double filtration (option) The green dec G 600 and G 700 negative pressure units can be equipped with double filtration (2x HEPA filters in series). When using double filtration, the maximum volume flow is reduced by approx. 10%.
Page 53
1st HEPA filter stage 2nd HEPA filter stage Clamping bar ▪ Reattach the clamping bars ▪ Attach pre-filter and pocket filter frames and insert filters Negative pressure unit green dec G 600, G 700 53 from 62 Original operating instructions Version 1...
11.1 Negative pressure unit green dec G 600 Image with optional double filtration Negative pressure unit green dec G 600, G 700 54 from 62 Original operating instructions Version 1...
Spare parts 11.2 Negative pressure unit green dec G 700 Image with optional double filtration Negative pressure unit green dec G 600, G 700 55 from 62 Original operating instructions Version 1...
Circuit diagrams Circuit diagrams 12.1 Negative pressure unit green dec G 600 SRE connect Negative pressure unit green dec G 600, G 700 56 from 62 Original operating instructions Version 1...
Page 57
Circuit diagrams Negative pressure unit green dec G 600, G 700 57 from 62 Original operating instructions Version 1...
Circuit diagrams 12.2 Negative pressure unit green dec G 700 SRE connect Negative pressure unit green dec G 600, G 700 58 from 62 Original operating instructions Version 1...
Page 59
Circuit diagrams Negative pressure unit green dec G 600, G 700 59 from 62 Original operating instructions Version 1...
Thoroughly cleaned (decontaminated) • with mounted transport / closing lid We expressly refer to possible additional regional and national regulations when storing the appliance technology. Negative pressure unit green dec G 600, G 700 60 from 62 Original operating instructions Version 1...
14.3 Waste The waste generated by the machine must be disposed of in a legally compliant, proper and professional manner. Negative pressure unit green dec G 600, G 700 61 from 62 Original operating instructions Version 1...
Safety of machinery - Safety distances to prevent hazard zones being reached by the upper and lower limbs (ISO 13857:2019) Name and address of the person authorised to compile the technical file: Boland, Thomas - deconta GmbH - Im Geer 20 - 46419 Isselburg Place: Isselburg Date: 21.03.2023...