200C Series
(Capacitive Ceramic)
Continuous Submersible Level Transmitter
Technical Specifications
Input Pressure Range
Level ft/H
O
2
Overpressure
Output Signal | Supply
Standard
Power Supply
Performance
Accuracy
Permissible Load
Influence Effects
Long Term Stability
Response Time
Thermal Effects | Offset and Span
Thermal Error
Temperatures
Operating Temperatures
Electrical Protection
Short-Circuit Protection
Reverse Polarity Protection
Electromagnetic Compatibility
Short-Circuit Protection
Electrical Connection
Jacketed Cable
3-Wire Cable with Integrated Air Tube for Reference to Atmospheric Pressure
Materials | Wetted
Housing
Seal
Diaphragm
Electrical Protection
Current Consumption
Weight Grams
Ingress Protection
CE-Conformity
14
20
34
psi
14X
14X
10X
4-20mA | 4-20mA + Hart 2 Wire | 0.5-4.5 VDC Ratiometric | 0-5 VDC | RS-485 3 Wire
4-20mA | 24 VDC || 0.5-4.5VDC Ratiometric || 0.5-4.5VDC } 5VDC || RS-485 HART } 24VDC
<±.25% Std | .125% Opt
R
= [(Vs-Vs
)/0.02 A]
max
min
Supply : 0.05% Full Scale / 10V
Load : 0.05% Full Scale / K
<± 0.1% Full Scale Over One Year
<150 msec or better
<± 0.2% FSO/K in Compensated Range -20°F - 178°F
PVC -32°F - 140°F
Permanent
No Damage to Sensor
Emission Immunity According to EN 61326
Permanent
PTFE | Teflon
®
-40 - 200°F
PVC | PP | PVDF | PTFE Teflon
FFKM - Kalrez
®
Pure Ceramic 99.9% AI203
Max. 25mA
PVC 575g | PP 475g | PVDF 825g | PTFE Teflon
IP 68
EMC Directive: 2004 | 108 | EC
54
10X
|
PP -20°F - 178°F
|
PVDF -40°F - 212°F
®
®
875g
www.iconprocon.com | sales@iconprocon.com | 905.469.9283
R
|
PTFE -40°F - 212°F
05
Need help?
Do you have a question about the Level pro 200C Series and is the answer not in the manual?