C
ASE OF DAMAGE
10.3 Leakage between the plug screw and the gauge body
Fig.1
Figure 1
• Tighten the torque of the locking screw
Figure 2
▪ If there is no improvement:
• Unscrew the screw plug
• Replace seal
(Pos.2)
• Check the sealing surface for contamination and damage.
Figure 3
• Screw in the screw plug
Page / 26
Fig.2
(pos. 1)
.
(Pos.1)
.
with the specified torque M
(pos. 1)
Fig.3
= 120 Nm.
d
D-02-B-51105-EN-02