9.5 Glass replacement

N
OTE
Property damage caused by damaged components
Apparently intact components can be damaged and lead to damage to the device when
reinstalled or reused.
Replace glasses and gaskets annually.
After loosening the clamping tabs, install completely new seals.
Create optimal operating conditions for the durability of the glasses and seals.
Figure 1
▪ The gauge must be depressurised
• Loosen and remove the pressure screws
The individual components
• Remove the clamping tabs
, glass
(pos. 3)
(pos. 5)
• Clean the sealing and contact surface surfaces of the display body with non-woven
fabric and check for damage.
Page / 22
Fig.1
Fig.3
(chap. 9.2)
(items 3,4,5,7 & 9)
, pressure plate
(pos. 7)
, seals
and screw holder
(pos. 4)
Fig.2
Fig.4
.
(pos. 6)
come loose.
.
(pos. 9)
D-02-B-51105-EN-02