Ulvac DTC-22A User Manual page 14

Diaphragm-type dry vacuum pump
Table of Contents

Advertisement

!
Note
Installation
(5)
Ingestion of liquids or compressed and gases into the pump will result in damage and prevent
proper operation.
(6)
Ingestion of rubbish and dust in the air entering the pump will interfere with its proper function. If
the air is likely to contain rubbish or dust, a filter should be fitted to the inlet to protect the pump.
(7)
Ducting should always be fitted to the pump outlet if toxic corrosive gases, or steam, enters the
pump.
Operation
(8)
Use the pump within an ambient temperature range of 40°C. Use at high ambient temperatures
will dramatically reduce the life of the pump.
(9)
Back pressure at the outlet while the pump is starting may overload the motor.
(10) The thermal protector operates when the pump reaches a very high temperature. Touching the
pump in this condition may result in burns.
(11) To maintain the performance of the pump, always ensure that it is cleaned internally after use.
Clean by ingesting clean air for 3~5 minutes under no-load conditions.
Maintenance and Repair
(12) The fine clearances used in this pump require skill in its assembly. If a repair technician is
unavailable, replacement of all consumables should be left to the manufacturer's service
division.