12. If these voltage readings are not within the specified limits, check for loose connections or broken
wires between the test points and the stator windings. If there are no wiring problems, the stator is
defective and should be replaced.
13. Perform the Case Cover Replacement Procedure.
Figure F.10 – 230 VAC receptacle locations
Figure F.11 – Output rectifier bridge lead locations
Fleet™ 400 Service Manual