Forza FDC-1002R-I User Manual

Forza FDC-1002R-I User Manual

Uninterruptible power supply system
Hide thumbs Also See for FDC-1002R-I:

Advertisement

Available languages

Available languages

Quick Links

User manual
Uninterruptible Power Supply System
FDC-1002R-I
Rackmount online UPS system

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FDC-1002R-I and is the answer not in the manual?

Questions and answers

Summary of Contents for Forza FDC-1002R-I

  • Page 1 User manual Uninterruptible Power Supply System FDC-1002R-I Rackmount online UPS system...
  • Page 2: Table Of Contents

    1. Introduction Thank you for purchasing the Forza FDC -1002R-I Online UPS. To enjoy all the features and benefits of this unit, please read and follow all installation and operation instructions thoroughly before unpacking, installing or operating this device. After you have read this 1.
  • Page 3: Maintenance, Service And Faults

    • Before carrying out any kind of service and/or maintenance, disconnect the batteries and verify that no current is present and no FDC-1002R-I hazardous voltage exists in the terminals of high capacity capacitors, such as BUS-capacitors. Servicing of batteries should be performed or supervised by experts who possess the knowledge to closely follow all required precautions.
  • Page 4: Ups Connections

    2.3.1 Initial setup Communication ports • For safety considerations, the UPS is shipped out from the factory with battery connectors unattached. To allow for unattended UPS shutdown/start-up and status monitoring, connect one end of the communication cable to the USB port, •...
  • Page 5: Advanced Operation

    3. Advanced operation 3-1. Description of buttons and functions UPS status Color Status LED 1 Green Lighted LED4 to LED7 load level indication in line mode. Green Lighted Line mode LED4: > 75% load LED5: 50% ~ 75% load LED6: 25% ~ 50% load LED7: 0% ~25% load Button Function...
  • Page 6: Audible Alarm

    6. Technical specifications The AC input is connected to the UPS Plug the power cord outlet to a wall socket. FDC-1002R-I General Capacity 1000VA/900W Even though the mains supply The internal or external battery is not Re-connect battery wires using the...
  • Page 7 Output Environment Nominal voltage 220/230/240VAC Operating temperature 32° F-104°F AC voltage regulation (battery ±1% Storage temperature -4° F-122° F mode) Relative humidity 20-90% non-condensing Frequency (synchronized range) 47-53Hz at 50Hz system / 57-63Hz Operating altitude <1000m at 60Hz system Every 100m above 1000m decreases output Frequency (battery mode) 50Hz ±...
  • Page 8 1. Introducción Gracias por preferir el Sistema UPS en línea FDC -1002R de Forza. Con el objeto de aprovechar todas las características y ventajas que ofrece esta unidad, haga el favor de leer y observar todas las instrucciones relativas a su instalación y funcionamiento antes de 1.
  • Page 9 Para un óptimo rendimiento, mantenga la temperatura ambiente entre 0° C y 40° C. Coloque la UPS a no • Unidad UPS menos de 20 cm de distancia de los monitores para evitar interferencia. • CD con Sofware ForzaTracker de Forza • Cable USB • Cable 13A IEC C13 a 5-15P •...
  • Page 10 2.3.1 Configuración inicial Conexión al puerto de comunicación • Por razones de seguridad, la fábrica envía la unidad de UPS con los conectores de la batería desconectados. Para permitir el monitoreo de estado y el apagado/encendido automático de la UPS, conecte el extremo del cable de comunicación al •...
  • Page 11 3. Funcionamiento avanzado 3-1. Descripción de botones y funciones Estado de la UPS Color Estado LED 1 Verde Iluminado LED4 a LED7 indicación del nivel de carga en modo de línea Verde Iluminado Modo de línea LED4: > 75% de carga LED5: 50% ~ 75% de carga LED6: 25% ~ 50% de carga LED7: 0% ~25% de carga...
  • Page 12 6. Especificaciones técnicas La entrada de alterna está conectada Enchufe el cable de CA en un a la salida de la UPS tomacorriente de la pared FDC-1002R-I Aspectos generales Capacidad 1000VA/900W A pesar de que el suministro La batería externa o interna no está...
  • Page 13 Salida Ambiente Tensión nominal 110220/230-240VCA Temperatura de funcionamiento 32°F-70°C Regulación de tensión de CA (modo ±1% Temperatura de almacenamiento -4°F-70°C de batería) Humedad relativa 20 -90%, no condensada Frecuencia (margen sincronizado) 47-53Hz con un sistema de 50Hz / 57-63Hz Altitud de funcionamiento <1000m con un sistema de 60Hz A una altitud superior a 1000m, la potencia...
  • Page 14 NOTES / NOTAS NOTES / NOTAS...