LAUNCH EM101N New Energy Oscillograph Multimeter User Manual WARNING Study, understand and follow all instructions provided with this product. Read these instructions carefully before installing, operating, servicing or repairing this tool. Keep these instructions in a safe, accessible place. Caution: To help prevent personal injury, follow the instructions below.
Page 4
LAUNCH EM101N New Energy Oscillograph Multimeter User Manual - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. www.diagtools.eu; info@diagtools.eu; Pernavas 43A-9, Riga, Latvia, LV-1009; +37129416069...
1 Overview 1.1 Product Profile This EM101N is composed of hardware and software. Hardware includes EM101N module and connection wire. The Oscilloscope and Multimeter APP are installed on diagnostic tool. Automotive oscilloscopes assist the auto repair technician with the ability to quickly identify faults on automotive electronic equipment and wiring.
Type A-Type B USB cable Used to connect EM101N and diagnostic tool, sending signal acquired by EM101N to diagnostics tool to display waveform. Power adaptor Used to charge the EM101N with included USB cable.
Page 8
LAUNCH EM101N New Energy Oscillograph Multimeter User Manual Input impedance 1MΩ±2%, 15pF±5pF parallel Vertical scale 10mV/div~10V/div Sample bit 8 bits Max. input voltage 40V peak value (DC + AC peak value) Probe attenuation coefficient 1X, 10X,100X (need probe support) Trigger type...
LAUNCH EM101N New Energy Oscillograph Multimeter User Manual 2 Component and Controls Number Name Description Fuse 10A current input port mAμA mA/ 400mA current input port Negative public port Voltage/resistance input terminal V/Ω * Note: The ports listed above are measurement ports for multimeter.
Page 10
Indicator LED Solid Green: Working normally. Channel 1 Channel 2 1. Charge the EM101N with power adaptor and USB cable. 2. Connect EM101N and diagnostic tool with USB cable to transmit data. I/O Port Note: The diagnostic tool is not able to provide power supply to EM101N.
LAUNCH EM101N New Energy Oscillograph Multimeter User Manual 3 Oscilloscope Operations 3.1 Initial Use 3.1.1 Getting Started Tap the Oscilloscope app icon and the following screen will appear: Note: If no proper connection is made, no waveforms will be displayed on the screen and most functions become disabled.
Page 12
Reference channel settings panel Setup reference channel. RUN/STOP/WAIT WAIT: All pre-triggered data has been acquired and the EM101N is ready to accept a trigger. STOP: The EM101N has stopped acquiring waveform data. RUN: The EM101N is running.
You can run the routine at any time but you should always run the routine if the ambient temperature changes by 10°C or more. For accurate calibration, power on the EM101N and wait twenty minutes to ensure it is warmed up. Calibration mainly includes simulation channel calibration, trigger voltage of trigger circuit calibration and non-linear calibration of horizontal base line deviation.
Tap Menu -> User Settings, then tap Automatic Calibration. Tap OK on the pop-up message box to start calibration. The LED on the EM101N starts flashing and the prompt message “Calibrating, please wait” will appear on the upper left corner of the screen.
Page 15
LAUNCH EM101N New Energy Oscillograph Multimeter User Manual 2. Connect the black terminal and signal wire (its other end connected to the red 4mm connector) of the 6-way breakout lead to the GND and signal terminal of the vehicle sensor.
Note: For better comparison and identification, each channel and waveform is marked in different color. The EM101N can display multiple waveforms simultaneously, but only one waveform is allowed to display at top. The top channel is called current channel displayed as 3.2.2 Channel Attributes &...
Page 17
Oscilloscope presents the acquired data on the screen. Go to Trigger, the following screen will appear: The EM101N applies edge trigger, which is the most commonly used and effective trigger method. A clear majority of applications apply this trigger method to trigger waveform. An edge trigger determines whether the Oscilloscope finds the trigger point on the rising/falling/dual edge of a signal.
The Oscilloscope has an auto-set feature that sets up the Oscilloscope automatically to display the input signal in a best fit. Tap Auto, the EM101N may change the current settings to display the signal. It automatically adjusts the vertical and horizontal scaling, as well as the trigger coupling and position.
Page 19
LAUNCH EM101N New Energy Oscillograph Multimeter User Manual Tap it to remove the measurement item. The values corresponding to the selected items will be displayed on the bottom of the screen. Parameter type Description Cycle Time for the first signal cycle to complete in the waveform.
Page 20
LAUNCH EM101N New Energy Oscillograph Multimeter User Manual Tap Clear to turn off all measurement items. 2. Save This function allows you to save the waveforms of the channels. Tap Save and the following screen will appear: Select the desired measurement channel, select file type (.WAV or .CSV), tap the default file name to change the file name and select save.
Page 21
LAUNCH EM101N New Energy Oscillograph Multimeter User Manual 4. User Settings This option provides access to data clearing, waveform display, auto calibration and oscilloscope parameter save and recovery. Tap User Settings and the following screen will appear: Item description: Clear Data: Clear saved data and user setup.
LAUNCH EM101N New Energy Oscillograph Multimeter User Manual 3.2.5 Car Test Operations This function provides all kinds of the testing applications on the automotive parts (including circuits, sensors, actuators, ignition etc.) and detailed connection methods. Tap Car test and the following screen will appear: Tap to select the desired automotive part, the system will automatically configure the option to the preset parameters.
1/△X: Frequency. 3.2.7 Quick Save This function is used to quickly save the currently running measurement waveform. The EM101N can save waveform of analog channel or mathematical channel to the local. Saved file format can be WAV or CSV.
2. Select DC voltage/AC voltage and corresponding range. Tap Not connected to search for EM101N. When it is successfully connected, the diagnostic tool will display connection status. 3. Insert one end of black test pen into COM terminal of EM101N, insert one end of red test pen into V/Ω terminal of EM101N.
When it is successfully connected, the diagnostic tool will display connection status. 3. Insert black test pen into COM terminal of EM101N. If measured current is above 400mA, insert red test pen into A terminal of EM101N. If measured current is below 400mA, insert red test pen into mAμA terminal of EM101N.
3. Insert black test pen into COM terminal of EM101N, insert red test pen into V/Ω terminal of EM101N. 4. Attach black and red test pen to metal part of resistance ends. Keep test pen firmly attached to resistance.
EM101N New Energy Oscillograph Multimeter User Manual 3. Insert black test pen into COM terminal of EM101N, insert red test pen into V/Ω terminal of EM101N. 4. Attach red test pen to positive end of diode, black test pen to negative end of diode. Keep test pen firmly attached to diode.
LAUNCH EM101N New Energy Oscillograph Multimeter User Manual connector, and use Resistance to test the resistance between the two terminals of the sensor. Its resistance value is inversely proportional to the temperature (negative temperature coefficient) and should be less than 1kΩ during warm-up.
EM101N New Energy Oscillograph Multimeter User Manual 5 Care & Maintenance General Care Do not store or leave the EM101N where the device will be exposed to direct sunlight for long periods of time. Caution To avoid damages to the device or probes, do not expose them to sprays, liquids or solvents.
Page 30
The exclusive remedy for any automotive meter found to be defective is repair or replacement, and LAUNCH shall not be liable for any consequential or incidental damages.