9:37 Tu 04.02.2020
Legend
A - Display
B - Navigation Dial
C - Mode Selector Dial
42
A
5,1°
55°
24.2
°
B
C
Vitocal 100-AW AM2V Installation, Service and Operating
Use the mode selection dial C to set one of the
modes:
Winter (Space heating + DHW)
Summer (Space Cooling + DHW)
Standby (Frost Protection Active)
Turning the navigation dial B (left or right), with
the winter or summer mode being active, switches
the function screens on the display A. To select
the desired menu item press on the navigation dial
B.
H Home Screen: indicates the basic parameters of
the heat pump (see the table for details),
H Diagnostics Menu: allows the input and output
signals of the heat pump to be viewed.
H Settings Menu: allows the heat pump parameters
to be adjusted to the user's preferences.
H Service Menu: allows for heating system
configuration to object's conditions (available to
the installer and service contractors though an
access code) and preview of input and output
heat pump's signals and current parameters.
H Time Schedule Override: Allows the homeowner
to override the active heating/cooling function
without needing to adjust the time schedule
Pressing and holding the navigation dial when in
any menu will return you to the home screen.
The individual functions are accessed by selecting
the relevant menu screen and pressing the
navigation dial. If an error or warning in the system
occurs, the home screen will display either a E E e rr or
1. By pressing on dial B, a list of detected errors
and warnings will be displayed.
+
z
+