Siemens SIMATIC MICRO-DRIVE PDC600 Equipment Manual page 41

Servo drive system
Table of Contents

Advertisement

1
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
Figure 5-1
Derating as a function of the mounting position
For vertical mounting (vertical mounting rail), the PDC600 may be operated up to a maximum
ambient temperature of 40 °C. A derating of the power output to 500 W must be observed; this
corresponds to a rated current of the power section of 9.1 A
Derating depending on the ambient temperature
For horizontal mounting (horizontal mounting rail), no restrictions are necessary for the
PDC600 up to an ambient temperature of 40 °C.
A derating of 2.5%/K must be observed up to a maximum temperature of 60 °C. The motor
current must be reduced.
Note
Note the simultaneity factors of the inputs/outputs in this section.
The figure below shows the maximum permitted output current of the power unit as a
function of the ambient air temperature for the derating.
PDC600(F)
Equipment Manual, 12/2023, A5E50502703-AB
0
1000
2000
Derating for PDC600(F) as a function of the installation height
3000
4000
Technical specifications
5.2 Drive controller derating
.
eff
39