Siemens SIMATIC MICRO-DRIVE PDC600 Equipment Manual page 27

Servo drive system
Table of Contents

Advertisement

Table 3-2
Pin
• Pin assignment: Interface X5060 for supply voltage of logic supply of PDC
Table 3-3
Pin
The logic supply voltages 1L+, 2L+ with associated ground potentials 1M, 2M are electrically isolated from
one another.
Connection of supply voltage for the power unit (24 V DC to 48 V DC)
The figure below shows the connection of the 24 V DC to 48 V DC supply voltage for the power
unit to the interface X5050:
Figure 3-3
• Pin assignment: Interface X5050 for power supply of power unit
Table 3-4
Designation
Connecting of solid conductors and stranded conductors (stranded wire) with end sleeve
To connect a wire, proceed as follows:
1. Strip 8 to 11 mm of insulation from the wires.
2. Crimp the stranded conductors with end sleeves.
3. Insert the wire into the spring-loaded terminal as far as it will go.
PDC600(F)
Equipment Manual, 12/2023, A5E50502703-AB
Pin assignment: Interface X4060 for supply voltage of inputs/outputs
Designation
1
2M
Reference potential
of supply of inputs/
outputs
3
2L+
Supply of inputs/
outputs
Pin assignment: Interface X5060 for supply voltage of logic supply of PDC
Designation
1
1M
Reference potential
of logic supply of PDC
3
1L+
Logic supply of PDC
Connection of power unit supply
Pin assignment: Interface X5050 for supply of power unit
4L+
Power supply of power unit
4M
Reference potential of power supply of power unit
Function
Pin
2
4
Function
Pin
2
4
Function
3.3 Connecting the supply voltages
Designation
Function
2M
Reference potential
of supply of inputs/
outputs
2L+
Supply of inputs/
outputs
Designation
Function
1M
Reference potential
of logic supply of PDC
1L+
Logic supply of PDC
Connecting