LG PREMTC00U Owners & Installation Manual page 277

Simple wired remote controller
Table of Contents

Advertisement

F
MULTI
F
MULTI
MAX
Figure 100: Multi F LMU247HV system Power Wiring and Communications Cable.
L1
L2
Three-wire Power Wiring
(Including Ground)
1(L1)
Indoor Unit Terminal Block
POWER WIRING
COMMUNICATIONS CABLE
• All field-supplied wiring, components, and materials should follow national, state, and local codes and requirements.
• Use only stranded, shielded copper conductor.
• Ground wiring is required to prevent accidental electrical shock during current leakage, communication problems from electrical
noise, and motor current leakage. Do not connect the ground line to the pipes.
• Install a main shutoff switch or circuit breaker that interrupts all power sources simultaneously.
• Wiring cable size must comply with applicable national, state, and local codes.
Power Wiring (208-230V) and Communications Cable Details
Power Supply
Main Switch
L1
L2
Circuit Breaker
Fuse
2(L2)
3
1(L1)
2(L2)
Indoor Unit Terminal Block
Unit A
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
WIrInG ConneCtIons
G
Outdoor Unit Terminal Block
L1
L2
1(L1) 2(L2)
3
1(L1)
2(L2)
Indoor Unit Terminal Block
Unit B
Unit C
Outdoor Unit
3(A)
3(B) 1(L1)
2(L2)
3(C)
3
WIRING CONNECTIONS | 225