ERRoR
MESSAGES
13
ERROR MESSAGES
Under certain conditions the Covermeter will display error messages (Figure
21)
These messages
are
normally cleared by pressing any one of the
softkeys
The cause of the error
will
be indicated
by
the message and should
be
corrected before proceeding
Table 1:
Error messages
Error
message
Causes
Action to
take
#1
-
PROBE
Search
head{o-gauge
communication failure
Remove search head and refit
lf error oersists. return
to
Elcometer*
#2
-
PROBE
Corrupt data output
from
probe
Try
new search
head
lf error oersists, return
to
Elcometer*
#3
-
PROBE
lnternal
error
Return
to
Elcometer*
#4
-
PROBE
Search head power supply
fault
Remove
probe
lf
error persists, the
Covermeter
is
faulty
lf error clears, the
probe
is
faulty
Return
faulty
part
to Elcometef
#5
-
PROBE
Internal
error.
Remove search head and reiit
lf
error
Dersists,
return
to
Elcometer*
PROBE
UNSUPPORTED
Old
Covermeter software does
not support new search head
Return
to Elcometer* for software
upgrade
PROBE CHANGED
Probe has been changed and
is not
comoatible with current
batch
Change to probe used when batch was
created
VALUE
TOO
LARGE
Numerical
error
Switch Covermeter
off
then on again
lf
error oersists contact
Elcometer.
CLOCK
lnternal
error.
Return
to Elcometer*
LANGUAGE
MEMORY
Software error
Return to
Elcometef
* Contact Elcometer
or
your Elcometer Supplier
to
arrange
return
[2 -
FROEE
ERRBR-FREss
ff
HEV
BAR
ZERI]
Figwe
21. Example
error
message
-
search
head
not connected