Diaphragm Repair - Graco Husky 1040 D71 Instructions-Parts List Manual

Acetal, polypropylene, and pvdf air-operated diaphragm pumps
Table of Contents

Advertisement

Diaphragm Repair

Tools Required
D Torque wrench
D 10 mm socket wrench
D 19 mm open–end wrench
D Adjustable wrench
D O-ring pick
D Lithium-base grease
Fig. 12
Service
Disassembly
NOTE: A Fluid Section Repair Kit is available. Refer to
page 25 to order the correct kit for your pump. Parts
included in the kit are marked with an asterisk, for
example (401*). Use all the parts in the kit for the best
results.
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 11.
1. Relieve the pressure.
2. Remove the manifolds and disassemble the ball
check valves as explained on page 18.
3. Using a 10 mm socket wrench, remove the screws
(106 and 112) holding the fluid covers (101) to the
air covers (23). Pull the fluid covers (101) off the
pump. See Fig. 12.
You must torque the eight long screws (106) first, then the short
1
screws (112). Torque to 130 to 150 in-lb (14 to 17 NSm). See
Torque Sequence, page 30.
Arrow (A) must point toward air valve (B).
2
B
23
112
1
WARNING
101
2
A
113
106
1
308443
04162B
19