Amplitude Units
Acceleration.................................. g, m/s
Velocity........................................... mm/s
Displacement ............................... mm
Battery Type.................................. 2 AAA, IEC LR03
External Piezoelectric Accelerometer
DC Bias Voltage ........................... 6 V dc to 7 V dc
DC Bias Current ........................... 3.5 mA
Other specifications are the same as those of the built-in
piezoelectric accelerometer.
Battery Life .................................... 25 hours
Size (L x W x H) ............................. 24.1 cm x 7.1 cm x 5.8 cm
Weight............................................. 220 g
Audio Port...................................... Stereo Audio Output Jack
External Sensor Port .................. M12 connector
Environmental
Operating Temperature............. -10 °C to 50 °C
Storage Temperature................. -30 °C to 60 °C
Operating Humidity .................... 30 % to 90 % (non-condensing)
Operating Altitude ...................... 2000 m
Storage Altitude .......................... 12 000 m
IP Rating ......................................... IP 40
2
Note
(3.5 mm Audio Plug)
Vibration Limit .............................. 500.0 m/s² peak
Electromagnetic Compatibility
International.................................. IEC 61326-1: Portable
CISPR 11 ........................................ Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses
conductively-coupled radio frequency energy that is
necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments
other than domestic and those directly connected to a low-
voltage power supply network that supplies buildings used
for domestic purposes. There may be potential difficulties in
ensuring electromagnetic compatibility in other
environments due to conducted and radiated disturbances.
Emissions that exceed the levels required by CISPR 11 can
occur when the equipment is connected to a test object. The
equipment may not meet the immunity requirements of this
standard when test leads and/or test probes are connected.
Korea (KCC) ................................... Class A Equipment (Industrial
Class A: Equipment meets requirements for industrial
electromagnetic wave equipment and the seller or user
should take notice of it. This equipment is intended for use in
business environments and not to be used in homes.
Vibration Meter