5.2.1 COMBUSTION FUNCTIONS MENU
Touch the P3 button to enter the submenu. You can enter the Combustion
Management menu again with the P3 button. In the Combustion Management menu, there
are Level, Auger Calibration and Fan Calibration menus.
5.2.1.1. LEVEL
In this menu, the pellet combustion speed can be changed with the help of P4 and P6
buttons. Ex: 1 - 2 - 3 - 4 - 5 – 6 - A (A = Auto) Use P3 to save.
5.2.1.2. AUGER CALIBRATION
Enter the pellet loading speed settings with
P3. Use P4 and P6 to slow the pellet
loading speed or adjust the acceleration values in the display ( +7...0...-7 ). Use P3 to
save. Use P1 ESC to exit the menu.
5.2.1.3. FAN CALIBRATION
Enter with the P3 button for fan speed control. Use P4 and P6 to slow down the chimney
fan speed or set acceleration values in the display ( +7...0...-7 ). Use P3 to save. Use P1 ESC
to exit the menu.
5.2.2. HEATING MANAGEMENT
Press the P3 button to enter the submenu. You can enter the Heating Management
menu again with the P3 button. Boiler thermostat, heating power and summer-winter
menus are avaliable in the Heating Management menu.
5.2.2.1. BOILER THERMOSTAT
Press the
P3 button to enter the submenu. To change the boiler thermostat level
press
P4 and
P6. It can be set in max.75- min 50. Use P3 to save.
5.2.2.2. HEATING POWER
Press the
P3 button to enter the submenu. Use
P4 and
P6 to change the
blowing fan values. Ex: 1 - 2 - 3 - 4 - 5 - 6 - A (A = Automatic Blowing) Use the P3 button
to record
5.2.2.3 SUMMER- WINTER MENU
Press the
P3 button to enter the submenu. With
P4 and
P6 button,
winter mode can be selected and with
P3 button you can save it. Use P1 ESC to
exit. (Summer mode only applies if there is a hot water boiler system.)
5.2.3 REMOTE CONTROL MENU
Remote control is not available