Teba therm TP-16 Installation And User Manual

Pellet central heating stove - boiler

Advertisement

Quick Links

Installation and User Manual
Model
TP-12 / TP-16 / TP-24/ TP-28 / TP-30
TP-25 / TP-35
Pellet Central Heating Stove - Boiler
EN
Tested according to DIN EN 14785

Advertisement

Table of Contents
loading

Summary of Contents for Teba therm TP-16

  • Page 1 Installation and User Manual Model TP-12 / TP-16 / TP-24/ TP-28 / TP-30 TP-25 / TP-35 Pellet Central Heating Stove - Boiler Tested according to DIN EN 14785...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. INTRODUCTION ........................3 2. FEATURES ........................... 3 3. WARNING ........................... 4 4. INSTALLATION AND CONNECTION ..................4 4.1 GENERAL ........................4 4.2 SAFETY .......................... 5 4.3 SANITARY ........................5 4.3.1 ELECTRICITY ......................6 4.3.2 FLUE PIPE CONNECTION ..................6 4.3.3 MINIMUM SAFETY DISTANCES ................
  • Page 3: Introduction

    We recommend you to keep this guide in order to reach the information about the correct use of the stove at the beginning of every winter. 2. FEATURES TECHNICAL TP-12 TP-16 TP-24 TP-28 TP-30 TP-25 TP-35...
  • Page 4: Warning

    3. WARNING ● USE ONLY 6MM NATURAL PELLETS MANUFACTURED ACCORDING TO DIN PLUS STANDARTS. ● DO NOT USE 8MM OR 10 MM PELET, OLIVE SEEDS, CHERRY SEEDS, HAZELNUT SHELL ETC. ● CLEAN THE FIRE POT EVERYDAY. ● THE FLAME TRANSMISSION PIPES MUST BE CLEANED WITH THE CLEANING MECHANISM.(PLEASE LOOK AT MAINTENANCE AND CLEANING PART) ●...
  • Page 5: Safety

    4.2 SAFETY * Product must be installed by an authorized person. * Before installing the product, it should be determined whether the bearing capacity of the floor to be installed is durable to the product. In case of insufficient bearing capacity, appropriate measures should be taken.
  • Page 6: Electricity

    person. After the installation, the leakage in the installation, radiators and valves should be checked and the air in the installation should be emptied. This all needs to be done by the authorized person. *According to the weather conditions of the region, it is recommended to use 1/3 portion antifreeze against corrosion and freezing.
  • Page 7 We recommend the use of twin(double) wall or twin(double) wall insulated system for chimney connection. • In the interior spaces, by using twin wall chimney system, exhaust gas can be throughed out to the outside, at the same time fresh air provided to inside. Twin insulated chimney should be used on the outside.
  • Page 9 ROOM THERMOSTAT CONNECTION POINT...
  • Page 10: Minimum Safety Distances

    4.3.3 MINIMUM SAFETY DISTANCES A 50 cm from rear wall B 40 cm from lateral wall C 100cm from front side Flammable materials and furniture should not be placed at a distance of 100 cm in the radiation area (C) of the flame monitoring cover.
  • Page 11: Control Panel

    5. CONTROL PANEL FUNCTIONS BUTTONS DESCRIPTION to exit from menu or submenu and to EXIT return previous menu Wait for 3 seconds by touching the P2 to ON- OFF switch on and off (Er05) Wait for 3-4 seconds by touching the P2 RESET to reset the error code MENU...
  • Page 12: Error Code And Explanation

    5.1. ERROR CODE AND EXPLANATION NOTE: When you encounter the error codes, firstly be sure stove and parts don’t work. You will see “BLOCK” on the screen. After checking and correcting the following connection, parts and values according to the error code, the error code must be cleared by -pressing the P2 for 3 seconds.
  • Page 13: Menu Functions

    radiators. Check the date and time Er11 Date and Time Error This error can occur due to pot pullution or Er12 Ignition failure error resistanse, check the resistance and clean the pot. Er15 Safety Low Voltage Check voltage fluctuation Display - Motherboard Check the display and the cable between Er16 connection error...
  • Page 14: Combustion Functions Menu

    5.2.1 COMBUSTION FUNCTIONS MENU Touch the P3 button to enter the submenu. You can enter the Combustion Management menu again with the P3 button. In the Combustion Management menu, there are Level, Auger Calibration and Fan Calibration menus. 5.2.1.1. LEVEL In this menu, the pellet combustion speed can be changed with the help of P4 and P6 buttons.
  • Page 15: Chrono Menu

    5.2.4. CHRONO MENU Press the P3 button to enter the menu. The display shows the Daily chrono management menu. Enter the modality menu by touching the Weekly Weekend P3 button. The screen on the right-up will appear. In the chrono menu, the daily / weekly / weekend time settings are usually switched on / off.
  • Page 16: Loading Menu

    5.2.5. LOADING MENU Press the P3 button to enter the submenu. It will manually load the pellet when it is turned ON with the P4 button. Pellet loading will stop by selecting OFF mode. Use P1 ESC to exit. (This is only a process to fill the pot and accelerate the ignition during the first burning phase when the product is in the OFF mode.
  • Page 17: System (Parameters) Menu

    5.2.9. SYSTEM (PARAMETERS) MENU FOR AUTHORIZED SERVICE. OUR COMPANY IS NOT RESPONSIBLE FOR ANY DAMAGES İN CASE USER ENTERS IN SYSTEM MENU AND CHANGE THE PARAMETERS 6. CLEANING AND MAINTENANCE TP-12 / TP-16 / TP- 24 / TP-28 / TP-25...
  • Page 18 TP-30...
  • Page 19 DP-35 Sections to clean Cleaning Frequency Daily (Through moving manual cleaning Flame Transmission Pipes Cleaning mechanism handle 4-5 times) Firepot Cleaning Daily Ash tray 1 Cleaning Daily Ash tray 2 Cleaning Once 10 days Flue Pipes Cleaning Once a month Chimney Cleaning Twice a year...
  • Page 20: Flame Pipes Cleaning

    6.1 FLAME PIPES CLEANING TP-12 / TP-16 / TP- 24 / TP-28 / TP-25 TP-30...
  • Page 21 For the cleaning of the flame transmission pipes, manual cleaning mexhanism handles will be used. These handles are placed under the top plate for TP-16, TP-24, TP-30 AND TP-25 models, also placed inside the top cover for TP-35 model. Cleaning frequency...
  • Page 22 TP-30...
  • Page 23: Combustion Pot Cleaning

    6.2. COMBUSTION POT CLEANING The firepot which is used on our products is easy-to-replace. When you pull it, it will be moved out easily. You should clean it daily. 6.3 ASH TRAY 1 AND ASH TRAY 2 CLEANING The ashtray 1 and ashtary 2 which is placed under the firepot is easy-to-replace. When you pull them, they will be moved out easily.
  • Page 24 Our company is not responsible for damages caused by running without water. Our company is not responsible for any damage that may occur in case of any voltage drop or rise. The damages can be occured related to sanitary are not covered by the warranty. Our company is not responsible for any damages in case user enters in system menu and change the parameters.
  • Page 25 PRODUCER AUTHORIZED Company Name : Aral Makina Company Name Madeni Eşya San. Ve Tic.Ltd. Şti Address : Organize Sanayi Bölgesi Address : 8.Cad. No: 16 Melikgazi / KAYSERİ Tel : +90 0 352 321 28 11 Tel : Fax : +90 0 352 321 28 14 Fax : E- posta : E- posta :...

This manual is also suitable for:

Tp-12Tp-24Tp-28Tp-30Tp-25Tp-35

Table of Contents