Teba therm T-17 Installation Manual

Central heating stove with solid fuel

Advertisement

Quick Links

Installation & Manual
EN
Models:
T-17 / TF-25 / T-25 / T-29 / T-21 T-22 /
T-22 Plus / TF-25 Plus / T-29 Plus
Central Heating Stove With Solid Fuel
Tested according to DIN EN 13240
For product efficiency and emission values, see the declaration of
conformity!

Advertisement

Table of Contents
loading

Summary of Contents for Teba therm T-17

  • Page 1 Installation & Manual Central Heating Stove With Solid Fuel Models: T-17 / TF-25 / T-25 / T-29 / T-21 T-22 / T-22 Plus / TF-25 Plus / T-29 Plus Tested according to DIN EN 13240 For product efficiency and emission values, see the declaration of...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. INTRODUCTION ..............................3 2. GENERAL INFORMATION ............................ 4 3. SAFETY ................................. 4 4. INSTALLATION ASSEMBLY AND CONNECTION ....................5 4.1 SAFETY DISTANCES (MINIMUM DISTANCE) ....................5 4.2 STOVE INSTALLATION AND CONNECTION ....................6 4.2.1 Expansion Tank ............................6 4.2.2 Circulation Pump ............................
  • Page 3: Introduction

    1. INTRODUCTION Central heating stoves provide a comfortable and easy-to-use interior aqueous system. These heating units combine pleasure with a fireplace view. It is an independent heating unit that provides heat dissipation of radiators, heat distribution to the whole house and hot water through heat exchanger or boiler. The stove body is made of steel and the food heating chamber is made of Teflon or enamel coating.
  • Page 4: General Information

    2. GENERAL INFORMATION National Standards, European Standards, local regulations, construction regulations, fire protection and safety regulations must be observed. During the installation, one must contact a person who is authorized for the chimney. The authorized person shall check the shape of the chimney connection of the product in the prescribed directions.
  • Page 5: Installation Assembly And Connection

    *** The stove should not be used without water.*** 4. INSTALLATION AND CONNECTION The packaging of the stove protects the product from damage in the best possible way. However, the stove or its accessories may still be damaged during transport. Therefore, after removing the stove from the package, check whether it is complete and undamaged.
  • Page 6: Stove Installation And Connection

    Flammable materials and furniture should not be placed at a distance of 80 cm in the radiation area (C) of the flame monitoring cover. This distance can be reduced to 40 cm when the protection panel is placed between the stove and the materials that are likely to burn. Minimum distances for flammable materials and furniture are indicated on the product label and must not be exceeded.
  • Page 7: Circulation Pump

    CAUTION! When filling, the installation has to be carried out from any point of the installation other than the expansion tank and the other outlet on the side should be closed with a blind plug, but the vapor output (water discharge) on the expansion tank must not be closed.
  • Page 8: Indicator Panel

    First of all, burn 10 -15 min 3 - 4 Parts at least at max. Wood (Around. 3,5 - 4 Temperature (90Cº) Open After set to the temperature you need. First of all, burn 15-20 min at least at max. Coal (Around 3,5 - 4 Temperature (90Cº)
  • Page 9: Chimney Connection

    heat safety valve (power failure, etc.), and the boiler water temperature rises to 95 ºC, it opens the way of the heat exchanger to allow the cold water to circulate in the boiler and helps to reduce the heat of the boiler water and prevent it from going out again.
  • Page 10: Stove Work Principles

    CAUTION: Depending on the climatic conditions of the regions, certain amounts of antifreeze must be added. Our company is not responsible for any damages caused by not using antifreeze. CAUTION: The plumbing pipes should not be routed as far as possible through concrete floors and should be isolated if required.
  • Page 11: Combustion And Heating

    CAUTION: Fill the expansion tank halfway through water supply. Before the activation of the stove, the labels (except the plate) on the stove and the accessories in the ashtray or fire chamber needs to be removed, as it is only valid for shipping protection.
  • Page 12: Ashtray Discharge

    5.3.3 Ashtray Discharge After a long period of combustion, at least once a day, the ash should be transferred from the grid to the ash tray by using the ash-handle. We advise you to do this when the stove is cold. When half of the ashtray is filled, draining should be considered. If the ashtray is full, cast-iron parts will stay between the fuel chamber and ash, and the air-take will be impossible.
  • Page 13: Problem And Causes

    6.1 PROBLEM AND CAUSES Reasons why the stove does not Solution heat or smoke coming out Check the chimney efficiency. Clean The stove or the stove-pipe let your stove and stove pipes on time ( see smokes continuously the chimney assembly scheme ) Check the connection.
  • Page 14 defects starts from the actual delivery date. An invoice must be presented for inclusion in the warranty. Pump + glass + electric current high/low voltage resulted to a digital card failure + user errors are not covered by the warranty. In case of any damage related to production in our product, our company will try to repair this damage as soon as possible within the warranty period or it will replace the problematic part.