Teba therm TP-12 Installation & Manuals

Pellet stove with central heating system
Hide thumbs Also See for TP-12:

Advertisement

Installation & Manuals
TR
İMALATCI:
ARAL MAKINA LTD
TR-38070 KAYSERI/TÜRKEI
Pellet Stove With Central Heating
System
Model TP-12
T +90-352 321 28 12
F +90-352 321 28 14
DIN EN 13240
Tested according to
Tip BA 1
Please, see enclosed declaration of conformity for
efficiency and emission
www.teba.com.tr
info@teba.com.tr

Advertisement

Table of Contents
loading

Summary of Contents for Teba therm TP-12

  • Page 1 Installation & Manuals Pellet Stove With Central Heating System Model TP-12 DIN EN 13240 Tested according to Tip BA 1 Please, see enclosed declaration of conformity for efficiency and emission İMALATCI: ARAL MAKINA LTD T +90-352 321 28 12 www.teba.com.tr TR-38070 KAYSERI/TÜRKEI...
  • Page 2: Table Of Contents

    Contents Introduction General Information Safety Safety Distances(minimum distance) 6-7-8 Installation and Connections Electricity Plumbing Chimney Connection Control Panel Buttons Leds Display Errors Menu 4.5.1 Combustion Power Menu 4.5.2 Heating Power Menu 4.5.3 Boiler Thermostat Menu 4.5.4 Buffer Thermostat Menu 4.5.5 Room Thermostat Menu 4.5.6 Remote Keyboard Menu...
  • Page 3 Stove Work Principles Suitable Fuel 16-17 Cleaning and Maintenance 5.2.1 Cleaning Fire Transition Pipes 5.2.2 Cleaning Combustion Box General Warranty Warranty Policies Complaints Informations to Order Spare Parts...
  • Page 4 Pellet stoves which is environment friendly and provide comfortable and easy-to-use interior aqueous and dry system, have taken place of dry stoves which used in Turkey and over the World. Pellet stoves is used to heat some areas like homes, work places…etc. These are heating units that combine pleasure with fireplace view, comfort with its efficiency and fuel save;...
  • Page 5: Introduction

    1.0 Introduction Consumption of Pellet (environmental fuel) that is preferred by all European countries It has no risk for poisoning since it doesn’t contain carbon monoxide Electronical control system Automatical ignition To set-up of combusti on speed at 5 stage To keep the boiler water temperature at a requested temperature Remote Control system To blow air...
  • Page 6: General Information

    2.0 General Informations All required standart examinations have been made for your product. Predicted parameters associated with combustion efficiency and exhaust gas emissions are observed. The conformity of the product described in this manual was tested in IMQ Primacontrol Laboratory Pellet stoves provide comfortable and easy use through heating radiators, blowing hot air to ambient and fireplace view.
  • Page 7 20 cm from back wall 20 cm from lateral Wall and 80cm from radiation area In the radiation field of the flame monitor cover (C), at 80 cm distance, combustible materials and furniture should notbe placed. This distance can be reduced to 40cm when the protection panel which inhibits the passage of heat is put between stove and combustible materials.
  • Page 8 BACK WALL RADIATION AREA You can order floor protection plate from seller when you require.
  • Page 9: Installation And Connections

    3.0 Installation and Connection Product assembly and plumbing connection must be installed also by authorized person. Pellet stove is a full automatic device. Expansion tank, circulation pump, thermostat, safety valve, switch, sensor and similar parts are located inside the stove safely. 3.1.
  • Page 10: Control Panel

    4.0 Control Panel 4.1 Buttons 4.2 Leds *Only for plumbing with Flow Switch...
  • Page 11: Display

    4.3 Dısplay 4.4 Errors...
  • Page 12: Menu

    4.5 Menu Push P3 button to enter in the User Menu Using P4 and P6 buttons it is possible to select the desired Menu or Submenu. Push P3 button to enter in desired Menu or Submenu. To decrease or increase value push the buttons P4 or P6; to save the new vale push the button P3; to cancel the modifies and restore the old parameter’s value push the button P1.
  • Page 13: Room Thermostat Menu

    4.5.5 Room Thermostat Menu Menu which allows to modify the Room Thermostat’s value. 4.5.6 Remote Keyboard Menu Menu which allows to enable the Room Thermostat of the Remote Keyboard. 4.5.7 Chrono Menu Menu to set the time to switch on and off the stove or the boiler. It has 2 Submenu: Modality and Program.
  • Page 14: Week-End

    4.5.9.3 Week-End Choice between "Monday-Friday" and "Saturday-Sunday". There are 3 time slots for each period. The 3 programs modality are saved separately: for example, if it is set the daily mode, the others mode aren’t modified. IMPORTANT: after the Chrono programming to switch on the system by Chrono it is necessary to enable the desired mode (Daily, Weekly or Week-End) from Modality Menu.
  • Page 15: Load Menu

    The system has 10 calibration’s steps (the 0 value is set by the factory). For each step the value is increased or decreased of a per cent value (the per cent value is set in the Step Calibration Menu of System Menu).
  • Page 16: Set Contrast

    4.5.16.1 Set Contrast This Menu allows to set the display contrast. Push the buttons P4 and P6 to increase or decrease the contrast; P3 to save and exit, P1 to exit without save. 4.5.16.2 Set Minimum Light This Menu allows to set the display light when you don’t push any button. 4.5.17 System Menu THIS MENU IS FOR AUTORIZED PERSON.
  • Page 17: Cleaning And Maintenance

    It is not necessary to cut trees for commercial pellet. Wood wastes are used and so it can be burned easily. Also, it contributes to avoid forest fire since wastes are collected It needs smaller area compared to wood During using other solid fuels, creosote occurs on chimney and for pellet there is almost no creosote. Thus it is not neccessary to connect to a chimney, smoke can be given outside directly from its chimney output 5.2 Cleaning And Maintenance...
  • Page 18: Cleaning Combustion Box

    Daily or weekly. 6.0 General Warranty Warranty Policies TEBA THERM provide guarantees to the buyer within the framework of legal provisions. Two-year warranty periode which starts from the date of delivery, to benefit from warranty legal policies please keep your bill.
  • Page 19: Informations To Order Spare Parts

    Informations to Order Spare Parts You should contact your spare parts provider. Attention!!! Stove place should not be changed. Only advised and approved spart parts of manufacturer should be used. In case of need please contact your dealer or provider. After the publication of this manuel, the company reserves the right to make changes.

Table of Contents